How To
Summary
This article describes in detail how to rebuild a corrupted VSAM user catalog using VSESP.USER.CATALOG as an example.
Objective
Rebuilding a VSAM catalog is the only way to repair a corrupted catalog.
Environment
Applicable for z/VSE 6.2 and previous releases of z/VSE.
Steps
Preparatory Steps
- Before you start rebuilding a VSAM user catalog, please verify that MINI startup is working, as it is required for step 7.
- Prepare and run a LISTCAT and VTOC Display for step 8.
* $$ JOB JNM=LISTCAT,CLASS=A,DISP=D,NTFY=YES // JOB LISTCAT SHOW CATALOG SPACE // EXEC IDCAMS,SIZE=AUTO LISTCAT SPACE ALL - CATALOG (VSESP.USER.CATALOG ) /* /& * $$ EOJ
* $$ JOB JNM=DITTODVT,CLASS=A,DISP=D,NTFY=YES // JOB DITTODVT PRINT VTOC FOR DOSRES AND SYSWK1 // UPSI 1 // EXEC DITTO $$DITTO DVT INPUT=VDOSRES,DSNAME=Z999999%.**,SORTBY=EXTENT $$DITTO DVT INPUT=VSYSWK1,DSNAME=Z999999%.**,SORTBY=EXTENT $$DITTO EOJ /* * OTHER DISKS AS IN LISTCAT SPACE ALL ??? /& * $$ EOJ
Step 1
Stop any applications (for example CICS, ICCF, VTAM, ...) which access VSAM files resident in the VSAM user catalog VSESP.USER.CATALOG (VSESPUC). This may include applications that access VSE/AF libraries in VSAM or DL/I databases in VSAM.
Step 2
Back up all VSAM files belonging to the VSAM user catalog VSESP.USER.CATALOG. Run IDCAMS BACKUP(*) in order to back up all the data sets from your user catalog. Use the parameter EXCLUDE to bypass corrupted files.
Step 3
Back up any VSE libraries from VSESP.USER.CATALOG using the Librarian. Since IDCAMS BACKUP ignores NOCIFMT files, you need to back up your VSE libraries separately. Please use LIBR BACKUP for that. For your VSESP.USER.CATALOG this is relevant to:
- VSE.PRIMARY.LIBRARY
- VSE.DFHHTML.LIBRARY
Step 4
Prepare DEFINE jobs for VSESP.USER.CATALOG and related dataspaces as well as RESTORE jobs for VSAM files and VSE libraries. Please create a DEFINE job for your VSESPUC catalog and the dataspaces similar to the example below (using JCL from VSAMDEFS.Z in library IJSYSRS.SYSLIB):
// JOB DEFCAT
// DLBL IJSYSUC,'VSESP.USER.CATALOG',,VSAM
// EXEC IDCAMS,SIZE=AUTO
DEFINE USERCATALOG(NAME(VSESP.USER.CATALOG) -
VOL(SYSWK1) -
NOTRECOVERABLE -
ORIGIN(3525) -
TRK(150))
DEFINE SPACE(VOLUMES(DOSRES) -
ORIGIN(1080) -
TRK(2040)) -
CATALOG(VSESP.USER.CATALOG)
DEFINE SPACE(VOLUMES(SYSWK1) -
ORIGIN(3675) -
TRK(840)) -
CATALOG(VSESP.USER.CATALOG)
DEFINE SPACE(VOLUMES(SYSWK1) -
ORIGIN(14175) -
TRK(525)) -
CATALOG(VSESP.USER.CATALOG)
/*
For environment B add:
/. ENV90B
// EXEC IDCAMS,SIZE=AUTO
DEFINE SPACE(VOLUMES(SYSWK1) -
ORIGIN(16680) -
TRK(15000))
DEFINE SPACE(VOLUMES(SYSWK1) -
ORIGIN(31680) -
TRK(1500)) -
CATALOG(VSESP.USER.CATALOG)
/*
For environment C add:
/. ENV90C
// EXEC IDCAMS,SIZE=AUTO
DEFINE SPACE(VOLUMES(SYSWK1) -
ORIGIN(16680) -
TRK(30000))
DEFINE SPACE(VOLUMES(SYSWK1) -
ORIGIN(46680) -
TRK(1500)) -
CATALOG(VSESP.USER.CATALOG)
/*
Please add the restore job using IDCAMS command RESTORE OBJ (*) in order to restore all the VSAM files from the backup:
// ASSGN SYS004,cuu <<< CUU of backup tape
// TLBL BACKUP1,'TEST.USER.BACKUP',,'BACKUP' <<< tape label
// EXEC IDCAMS,SIZE=AUTO
RESTORE OBJECTS (*) -
CATALOG(VSESP.USER.CATALOG) - <<< user catalog name
STDLABEL(BACKUP1) -
NREW -
XREF -
BUFFERS(3)
/*
Please add the define job for "Compression Control Data Set" (CCDS) and for Default Model for each user catalog you restore:
// EXEC IDCAMS,SIZE=AUTO
DELETE (VSAM.COMPRESS.CONTROL) CL NOERASE PURGE -
CATALOG(VSESP.USER.CATALOG)
DEFINE CLUSTER -
(NAME (VSAM.COMPRESS.CONTROL) -
RECORDS (200 100) -
SHAREOPTIONS (4 4) -
RECORDSIZE (128 500) -
VOLUMES (SYSWK1) -
NOREUSE -
KEYS (44 0) -
TO (99366)) -
TO (99366)) -
DATA (NAME -
(VSAM.COMPRESS.CONTROL.@D@)) -
INDEX (NAME -
(VSAM.COMPRESS.CONTROL.@I@)) -
CATALOG (VSESP.USER.CATALOG)
DEFINE CLUSTER(NAME(DEFAULT.MODEL.ESDS.SAM) -
VOL(DOSRES SYSWK1) -
RECORDS (1 1) -
RECORDSIZE (2000 2000) -
RECORDFORMAT (UNDEF) -
REUSE -
SPEED -
NOALLOCATION -
NONINDEXED) -
CATALOG(VSESP.USER.CATALOG)
/*
Please compose the define job for the VSE Library files (e.g. VSE.PRIMARY.LIBRARY and VSE.DFHHTML.LIBRARY).
// EXEC IDCAMS,SIZE=AUTO
DELETE (VSE.PRIMARY.LIBRARY) CL NOERASE PURGE -
CATALOG(VSESP.USER.CATALOG)
DEFINE CLUSTER -
(NAME(VSE.PRIMARY.LIBRARY) -
VOLUMES(DOSRES SYSWK1) -
NONINDEXED -
NOREUSE -
RECORDFORMAT(NOCIFORMAT) -
SHR(3) -
TRK(75 225)) -
DATA (NAME (VSE.PRIMARY.LIBRARY.DATA)) -
CATALOG(VSESP.USER.CATALOG)
/*
Please compose the LIBR job to restore the VSE/AF libraries (PRIMARY and DFHHTML).
Step 5
Submit all the prepared jobs to the POWER Reader with the disposition L (* $$ JOB JNM=DEFINE,DISP=L,CLASS=0) in order to keep them in the queue.
Step 6
Disconnect the VSAM user catalog VSESP.USER.CATALOG from the VSAM master catalog. Run IDCAMS EXPORT DISCONNECT in order to remove the user catalog pointer from the master catalog:
// EXEC IDCAMS,SIZE=AUTO
EXPORT -
VSESP.USER.CATALOG -
DISCONNECT
/*
Step 7
IPL VSE with only VSE/POWER ("MINI" configuration). To do this, enter MSG BG during regular IPL as soon as BG comes up (right after JOB BGINIT starts). Then enter MINI when prompted.
Step 8
Delete VTOC entries of the VSAM user catalog VSESP.USER.CATALOG using IKQVDU. Please run IKQVDU utility and use the following responses in order to delete the entries belonging to your VSESPUC catalog. VSAM entry names must be prepared in advance, e.g. comparing VTOC listing with IDCAMS LIST SPACE ALL.
Sample output of IDCAMS LIST SPACE ALL with 2 volumes DOSRES and SYSWK1:
// EXEC IDCAMS,SIZE=AUTO
1S54I PHASE IDCAMS IS TO BE FETCHED FROM IJSYSRS.SYSLIB
IDCAMS SYSTEM SERVICES TIME: 19:34:32 12/18/2020 PAGE 1
LISTCAT SPACE ALL -
CATALOG (VSESP.USER.CATALOG )
IDCAMS SYSTEM SERVICES TIME: 19:34:32 12/18/2020 PAGE 2
LISTING FROM CATALOG -- VSESP.USER.CATALOG
VOLUME -------- DOSRES
. . .
DATASPACE
DATASETS--------------29 FORMAT-1-LABEL: ATTRIBUTES:
EXTENTS----------------1 CCHHR------X'00D0000B09' SUBALLOC
. . .
EXTENT-DESCRIPTOR:
TRACKS-TOTAL--------2040 BEG-CCHH-----X'00480000' SPACE-MAP-----------BF04FD0192031EFD0582
TRACKS-USED----------623
DATASET-DIRECTORY:
DSN----. . .
. . .
VOLUME -------- SYSWK1
. . .
DATASPACE
DATASETS---------------1 FORMAT-1-LABEL: ATTRIBUTES:
EXTENTS----------------1 CCHHR------X'012D000B0C' SUBALLOC
. . .
EXTENT-DESCRIPTOR:
TRACKS-TOTAL---------150 BEG-CCHH-----X'00EB0000' SPACE-MAP-----------96
TRACKS-USED----------150
DATASET-DIRECTORY:
DSN----VSESP.USER.CATALOG ATTRIBUTES--------(NULL) EXTENTS----------------3
. . .
DATASPACE
DATASETS---------------0 FORMAT-1-LABEL: ATTRIBUTES:
EXTENTS----------------1 CCHHR------X'012D000B0D' SUBALLOC
. . .
EXTENT-DESCRIPTOR:
TRACKS-TOTAL---------840 BEG-CCHH-----X'00F50000' SPACE-MAP-----------00FD0348
TRACKS-USED------------0
DATASPACE
DATASETS--------------17 FORMAT-1-LABEL: ATTRIBUTES:
EXTENTS----------------1 CCHHR------X'012D000B0E' SUBALLOC
. . .
EXTENT-DESCRIPTOR:
TRACKS-TOTAL---------525 BEG-CCHH-----X'03B10000' SPACE-MAP-----------5703FD01A40F
TRACKS-USED----------507
DATASET-DIRECTORY:
DSN----...
. . .
DATASPACE
DATASETS---------------0 FORMAT-1-LABEL: ATTRIBUTES:
EXTENTS----------------1 CCHHR------X'012D000B10' SUBALLOC
. . .
EXTENT-DESCRIPTOR:
TRACKS-TOTAL--------1500 BEG-CCHH-----X'08400000' SPACE-MAP-----------00FD05DC
TRACKS-USED------------0
. . .
BEG-CCHH describes start of each extent in hexadecimal representation. Converting it into decimal representation
DOSRES
TRACKS-TOTAL--------2040 BEG-CCHH-----X'00480000' =^= cylinder 72 track 0
SYSWK1
TRACKS-TOTAL---------150 BEG-CCHH-----X'00EB0000' =^= cylinder 235 track 0
TRACKS-TOTAL---------840 BEG-CCHH-----X'00F50000' =^= cylinder 245 track 0
TRACKS-TOTAL---------525 BEG-CCHH-----X'03B10000' =^= cylinder 945 track 0
TRACKS-TOTAL--------1500 BEG-CCHH-----X'08400000' =^= cylinder 2112 track 0
Sample output from DITTODVT:
DITTO/ESA for VSE 12/18/2020 (2020-353) 21:18 Page 2
$$DITTO DVT INPUT=VDOSRES,DSNAME=Z999999%.**
* * * * Device 0200, VOLSER=DOSRES, 3390 with 2225 cyls, 15 trks/cyl, 58786 bytes/trk * * * *
--- Data Set Name --- sorted by EXTENT ----- Ext Begin-end Reltrk, RECFM BLKSIZE Created Expires
1...5...10...15...20...25...30...35...40.... seq Cyl-hd Cyl-hd numtrks DSORG LRECL YYYY.DDD YYYY.DDD
Z9999996.VSAMDSPC.TD802E41.T62C9B7B 0 64 0 71 14 960,120 VS 0 0 2020.154 2099.366
Z9999992.VSAMDSPC.TD802E41.T6E3D085 0 72 0 207 14 1080,2040 VS 0 0 2020.154 2099.366 <<< part of VSESP.USER.CATALOG
Z9999992.VSAMDSPC.TD802E41.T6494168 0 209 0 376 14 3135,2520 VS 0 0 2020.154 2099.366
3 record(s) printed
$$DITTO DVT INPUT=VSYSWK1,DSNAME=Z999999%.**
* * * * Device 0201, VOLSER=SYSWK1, 3390 with 2225 cyls, 15 trks/cyl, 58786 bytes/trk * * * *
--- Data Set Name --- sorted by EXTENT ----- Ext Begin-end Reltrk, RECFM BLKSIZE Created Expires
1...5...10...15...20...25...30...35...40.... seq Cyl-hd Cyl-hd numtrks DSORG LRECL YYYY.DDD YYYY.DDD
Z9999992.VSAMDSPC.TD802E41.T66485B3 0 65 0 234 14 975,2550 VS 0 0 2020.154 2099.366
Z9999994.VSAMDSPC.TD802E41.T6C340BC 0 235 0 244 14 3525,150 VS 0 0 2020.154 2099.366 <<< part of VSESP.USER.CATALOG
Z9999992.VSAMDSPC.TD802E41.T6FC6E1C 0 245 0 300 14 3675,840 VS 0 0 2020.154 2099.366 <<< part of VSESP.USER.CATALOG
Z9999992.VSAMDSPC.TD802E41.T67BB6A6 0 586 0 849 14 8790,3960 VS 0 0 2020.154 2099.366
Z9999992.VSAMDSPC.TD802E41.T68BA064 0 850 0 944 14 12750,1425 VS 0 0 2020.154 2099.366
Z9999992.VSAMDSPC.TD802E41.T713604B 0 945 0 979 14 14175,525 VS 0 0 2020.154 2099.366 <<< part of VSESP.USER.CATALOG
Z9999992.VSAMDSPC.TD802E41.T69C5B20 0 980 0 1111 14 14700,1980 VS 0 0 2020.154 2099.366
Z9999992.VSAMDSPC.TD802E41.T73785E5 0 1112 0 2111 14 16680,15000 VS 0 0 2020.154 2099.366
Z9999992.VSAMDSPC.TD802E41.T74E439E 0 2112 0 2211 14 31680,1500 VS 0 0 2020.154 2099.366 <<< part of VSESP.USER.CATALOG
9 record(s) printed
$$DITTO EOJ
R RDR,PAUSEBG
reply to prompt with
0 // ID USER=...,PWD=...
0 // ASSGN SYS000,ANYDISK,VOL=DOSRES,SHR
0 // EXEC IKQVDU,SIZE=AUTO
Respond with:
0 SCRATCH DSN=Z9999992.VSAMDSPC.TD802E41.T6E3D085 <<< check VTOC & LISTCAT SPACE ALL to find correct one
0 YES
0 END
Then continue for SYSWK1:
0 ASSGN SYS000,ANYDISK,VOL=SYSWK1,SHR
0 EXEC IKQVDU,SIZE=AUTO
Respond with:
0 SCRATCH DSN=Z9999994.VSAMDSPC.TD802E41.T6C340BC <<< check VTOC & LISTCAT SPACE ALL to find correct one
0 YES
0 SCRATCH DSN=Z9999992.VSAMDSPC.TD802E41.T6FC6E1C <<< check VTOC & LISTCAT SPACE ALL to find correct one
0 YES
0 SCRATCH DSN=Z9999992.VSAMDSPC.TD802E41.T713604B <<< check VTOC & LISTCAT SPACE ALL to find correct one
0 YES
0 SCRATCH DSN=Z9999992.VSAMDSPC.TD802E41.T74E439E <<< check VTOC & LISTCAT SPACE ALL to find correct one
0 YES
0 END
Step 9
Run the following jobs to define a new VSESP.USER.CATALOG and Restore the data:
- IDCAMS job to define a new VSESPUC catalog and the dataspaces.
- IDCAMS job to restore VSAM files back into VSESPUC catalog.
- IDCAMS job to define CCDS and the VSE Library files.
- LIBR job to restore the libraries back into VSESPUC catalog .
Step 10
Now you are ready to re-IPL the system.
Document Location