IBM Support

PI31841: WHEN ISN01=N AND ISN08 IS PRESENT, COMPLIANCE CHECK IS NOT REJECTING THE DATA WHEN THE VALIDATION METHOD IS SET TO M

Subscribe

You can track all active APARs for this component.

 

APAR status

  • Closed as program error.

Error description

  • When the HIPAA Compliance Check maps validatilon mehthod is set
    to M (Map), the compliance check maps are not properly rejecting
    data when ISN01=N and ISN08 is present.
    

Local fix

  • WTXCQ - WTX00046129
    TR / TR
    Circumvention: Set the Validation_Method=C in the
    compliance_check_5010_parameter.dat file
    

Problem summary

  • Users affected:
    WebSphere Transformation Extender Pack for HIPAA
    
    Problem Description:
    Compliance check detects bad INS08 value when Validation_Method
    is set to B or C, but not when set to M
    
    Platforms affected:
    ALL
    

Problem conclusion

Temporary fix

Comments

APAR Information

  • APAR number

    PI31841

  • Reported component name

    WEBSPHERE HIPAA

  • Reported component ID

    5724M6100

  • Reported release

    440

  • Status

    CLOSED PER

  • PE

    NoPE

  • HIPER

    NoHIPER

  • Special Attention

    NoSpecatt / Xsystem

  • Submitted date

    2014-12-19

  • Closed date

    2015-01-19

  • Last modified date

    2016-07-05

  • APAR is sysrouted FROM one or more of the following:

  • APAR is sysrouted TO one or more of the following:

Fix information

  • Fixed component name

    WEBSPHERE HIPAA

  • Fixed component ID

    5724M6100

Applicable component levels

[{"Business Unit":{"code":"BU059","label":"IBM Software w\/o TPS"},"Product":{"code":"SSVSD8","label":"IBM Transformation Extender"},"Platform":[{"code":"PF025","label":"Platform Independent"}],"Line of Business":{"code":"LOB59","label":"Sustainability Software"}}]

Document Information

Modified date:
01 May 2020