A fix is available
APAR status
Closed as program error.
Error description
This APAR addresses the following issues: 1. When a rebind of the V4.2 plans / packages is performed, a BIND error "Contoken = ' 'X is not unique" can occur. . 2. The widget for the control file field does not allow the user to enter a control file name greater than 26 characters. Automation Tool allows 38 characters when customizing via TCz. . 3. FREQVAL and/or HISTOGRAM rebuild index column statistics are not saved after being added from panel HAA$STI1. . 4. Panel HAA$TSKA is not filled correctly after creating or updating a Runstats Maintenance Window. . 5. A S0C1 abend can occur in ISPF when issuing an Update command on panel HAA$ADMX. . 6. A -204 SQL error can occur on table SYSAUTO.ACTION from the Autonomic Actions panel (HAA$ALRT). . 7. A -204 SQL error can occur on table SYSAUTO.AUTORUNS_HIST from the Autonomic Execution History panel (HAA$ADEH). . 8. DB2 V7 validation and associated messages removed. . 9. If you specify the 'Default WLM environment' on the DB2 parameters in TCz, the stored procedure ADMIN_UTL_MONITOR is created with the first two characters of the WLM name truncated. . 10. When running DB2 V10 CM (compatibility mode) and building Automation Tool utilities with LISTDEFs and Group by Partition options, the following message 'HAAB366W Group Parts By for REORG TS turned off because DB2 V9 LISTDEF does not support more than one PARTLEVEL number' may occur. DB2 V10 CM does support more than one PARTLEVEL on LISTDEF and therefore the Group by Partition options should be honored.
Local fix
Problem summary
**************************************************************** * USERS AFFECTED: Users of DB2 Automation Tool. * **************************************************************** * PROBLEM DESCRIPTION: This APAR addresses the following * * issues: * * 1. When a rebind of the V4.2 plans / * * packages is performed, a BIND error * * "Contoken = ' 'X is not unique" can * * occur. * * 2. The widget for the control file * * field does not allow the use to enter * * a control file name greater than 26 * * characters. Automation Tool allows 38 * * characters when customizing via TCz. * * 3. FREQVAL and/or HISTOGRAM rebuild * * index column statistics are not saved * * after being added from panel HAA$STI1. * * 4. Panel HAA$TSKA is not filled * * correctly after creating or updating a * * Runstats Maintenance Window. * * 5. A S0C1 abend can occur in ISPF when * * issuing an Update command on panel * * HAA$ADMX. * * 6. A -204 SQL error can occur on table * * SYSAUTO.ACTION from the Autonomic * * Actions panel (HAA$ALRT). * * 7. A -204 SQL error can occur on table * * SYSAUTO.AUTORUNS_HIST from the * * Autonomic Execution History panel * * (HAA$ADEH). * * 8. DB2 V7 validation and associated * * messages removed. * * 9. If you specify the 'Default WLM * * environment' on the DB2 parameters in * * TCz, the stored procedure * * ADMIN_UTL_MONITOR is created with the * * first two characters of the WLM name * * truncated. * * 10. When running DB2 V10 CM * * (compatibility mode) and building * * Automation Tool utilities with * * LISTDEFs and Group by Partition * * options, the following message * * 'HAAB366W Group Parts By for REORG TS * * turned off because DB2 V9 LISTDEF * * does not support more than one * * PARTLEVEL number' may occur. DB2 V10 * * CM does support more than one * * PARTLEVEL on LISTDEF and therefore the * * Group by Partition options should be * * honored. * **************************************************************** * RECOMMENDATION: APPLY the PTF. * **************************************************************** Code has been changed to correct this condition.
Problem conclusion
APPLY the PTF.
Temporary fix
Comments
APAR Information
APAR number
PI27360
Reported component name
DB2 AUTOMATION
Reported component ID
5697G6300
Reported release
420
Status
CLOSED PER
PE
NoPE
HIPER
NoHIPER
Special Attention
NoSpecatt / Xsystem
Submitted date
2014-10-09
Closed date
2015-01-07
Last modified date
2015-02-03
APAR is sysrouted FROM one or more of the following:
APAR is sysrouted TO one or more of the following:
UI24263
Modules/Macros
HAA$$PRM HAA$ADMW HAA$FCOL HAA$MPRX HAA$OPVL HAA$ORSD HAA$REP0 HAA$TASK HAA$TPRU HAA$UCHX HAA$VIE2 HAA#AOBP HAA#AOIM HAA#AUTO HAA#BCLR HAA#BCTC HAA#BPRI HAA#BSQL HAA#BSTS HAA#BST7 HAA#BST8 HAA#BTMP HAA#CL HAA#CL7 HAA#CL8 HAA#DB2V HAA#DMAL HAA#DMSQ HAA#DXCI HAA#DXCL HAA#DXCT HAA#DXDB HAA#DXDI HAA#DXDN HAA#DXDS HAA#DXDT HAA#DXES HAA#DXEV HAA#DXIN HAA#DXIS HAA#DXI2 HAA#DXQD HAA#DXQN HAA#DXQS HAA#DXSG HAA#DXSI HAA#DXST HAA#DXSV HAA#DXTS HAA#DXT2 HAA#DXVD HAA#ECDS HAA#EDAY HAA#EMCS HAA#EMIC HAA#EMID HAA#EPRI HAA#ERSH HAA#ERSI HAA#ERSU HAA#ERTA HAA#ERTI HAA#ERT8 HAA#ERT9 HAA#ESCP HAA#ESTI HAA#ETGI HAA#EXCS HAA#EXUX HAA#HPSC HAA#ICPO HAA#ICP7 HAA#ICP8 HAA#ILOB HAA#IOPF HAA#IX HAA#IXN8 HAA#IXPT HAA#IXP8 HAA#IXP9 HAA#IX10 HAA#IX7 HAA#IX8 HAA#IX9 HAA#JPRI HAA#LDEP HAA#LOBC HAA#LOB7 HAA#LOB8 HAA#LPIO HAA#MPRI HAA#NTFB HAA#NTFM HAA#NTFU HAA#OBEX HAA#OPCL HAA#OPRI HAA#OPVD HAA#PDEP HAA#PITC HAA#PITS HAA#PLOG HAA#RALR HAA#RCFS HAA#RH HAA#RH10 HAA#RI HAA#RIV7 HAA#RIV8 HAA#SCHD HAA#SCPY HAA#SETP HAA#SQLE HAA#TABL HAA#TB HAA#TBPT HAA#TB7 HAA#TB8 HAA#TP HAA#TP10 HAA#TS HAA#TSS HAA#TSSA HAA#TS10 HAA#TS7 HAA#TS8 HAA#TS9 HAA#UOPC HAA#UPRI HAA#UTOB HAA#VERT HAA#XMLC HAA#YARC HAA#YCAL HAA#YCTL HAA#YDEL HAA@HPTB HAA@HPTS HAA@HPUC HAA@IOSC HAA@IOTB HAA@PROF HAA@SYMR HAADDLX HAADDLY HAAEXP1 HAAJO2A HAAJSTAT HAAM256E HAANOT1A HAANOT2A HAAOE1A HAAOE2A HAAPRF1A HAASQL1A HAA151E HAA18
Fix information
Fixed component name
DB2 AUTOMATION
Fixed component ID
5697G6300
Applicable component levels
R420 PSY UI24263
UP15/01/22 P F501
Fix is available
Select the PTF appropriate for your component level. You will be required to sign in. Distribution on physical media is not available in all countries.