PH24844: JENKINS PLUGIN DOES NOT SUPPORT ENVIRONMENT VARIABLES OR PARAMETERS IN THE RUN PERFORMANCE TEST BUILD STEP

Subscribe

You can track all active APARs for this component.

 

APAR status

  • Closed as program error.

Error description

  • The Jenkins plugin does not recognize jenkins environment
    variables/parameters and does not substitute for them.
    
    It would be nice to allow the Jenkins plugin to do variable
    substitution (see
    https://stackoverflow.com/questions/30512887/variable-substituti
    on-in-jenkins-plugin) for more details and supposed way to
    implement.
    
    This would be useful, for example, if I have a jenkins job with
    50 steps and want to switch which workspace it is using, instead
    of setting the workspace textfield in jenkins 50 different times
    it would be nice to update a jenkins environment variable one
    time.  Or for updating IM location if it were to change.
    

Local fix

Problem summary

  • ****************************************************************
    * USERS AFFECTED:                                              *
    * RPT Users                                                    *
    ****************************************************************
    * PROBLEM DESCRIPTION:                                         *
    * See error description                                        *
    ****************************************************************
    * RECOMMENDATION:                                              *
    ****************************************************************
    

Problem conclusion

  • Fixed
    

Temporary fix

Comments

APAR Information

  • APAR number

    PH24844

  • Reported component name

    PERF TESTER WIN

  • Reported component ID

    5724J9601

  • Reported release

    920

  • Status

    CLOSED PER

  • PE

    NoPE

  • HIPER

    NoHIPER

  • Special Attention

    NoSpecatt / Xsystem

  • Submitted date

    2020-04-28

  • Closed date

    2023-01-31

  • Last modified date

    2023-01-31

  • APAR is sysrouted FROM one or more of the following:

  • APAR is sysrouted TO one or more of the following:

Fix information

  • Fixed component name

    PERF TESTER WIN

  • Fixed component ID

    5724J9601

Applicable component levels

[{"Business Unit":{"code":"BU059","label":"IBM Software w\/o TPS"},"Product":{"code":"SSMMM5","label":"Rational Performance Tester"},"Platform":[{"code":"PF025","label":"Platform Independent"}],"Version":"920","Line of Business":{"code":"LOB45","label":"Automation"}}]

Document Information

Modified date:
31 January 2023