IBM Support

OA58842: VSAM EOV FAILURE IEC070I FOR RLS DATA SET ON ONE VOLUME

A fix is available

Subscribe

You can track all active APARs for this component.

 

APAR status

  • Closed as program error.

Error description

  • When a VSAM ESDS RLS data set is defined with a single volume
    (candidate) and a large record size (27999 27999 in the reported
    case), an extend (EOV) request will fail with RC 8 RSN x'1C' and
    IEC070I 104-0460. After a single record is put in the data set
    successfully.
    
    However, the same extend works if two candidate
    volumes are specified (i.e. VOLUME(* *)).
    
    ADDITIONAL SYMPTOMS:
    IEC070I 104-0460
    

Local fix

  • BYPASS/CIRCUMVENTION:
    define RLS data set with multiple candidate volumes
    

Problem summary

  • ****************************************************************
    * USERS AFFECTED:                                              *
    * All VSAM RLS users using ESDSs with                          *
    * one CI/CA and one candidate volume.                          *
    ****************************************************************
    * PROBLEM DESCRIPTION:                                         *
    * Attempts to extend an ESDS with only                         *
    * one CI/CA and one candidate volume                           *
    * will fail with IEC0701 104-0460.                             *
    ****************************************************************
    * RECOMMENDATION:                                              *
    ****************************************************************
    During EOV processing, VSAM RLS fails to obtain storage for a
    new extent due to passing an invalid parameter. The extend
    fails with MSGIEC0701 RC104 RSN0460, and the Put that caused the
    extend will fail with RC8 RSN0208001C.
    

Problem conclusion

  • EOV processing has been corrected to properly obtain the new
    extent, avoiding the problem.
     KEYWORDS: RLSPSP/K
    

Temporary fix

Comments

APAR Information

  • APAR number

    OA58842

  • Reported component name

    ICF CATALOG & I

  • Reported component ID

    5695DF105

  • Reported release

    240

  • Status

    CLOSED PER

  • PE

    NoPE

  • HIPER

    NoHIPER

  • Special Attention

    NoSpecatt / Xsystem

  • Submitted date

    2019-12-17

  • Closed date

    2020-04-20

  • Last modified date

    2020-06-01

  • APAR is sysrouted FROM one or more of the following:

  • APAR is sysrouted TO one or more of the following:

    UJ02704 UJ02705 UJ02707

Modules/Macros

  • IDAVRSE0
    

Fix information

  • Fixed component name

    VSAM REC LEV SH

  • Fixed component ID

    5695DF122

Applicable component levels

  • R240 PSY UJ02705

       UP20/05/29 P F005

  • R230 PSY UJ02704

       UP20/05/29 P F005

  • R220 PSY UJ02707

       UP20/05/29 P F005

Fix is available

  • Select the PTF appropriate for your component level. You will be required to sign in. Distribution on physical media is not available in all countries.

[{"Business Unit":{"code":"BU054","label":"Systems w\/TPS"},"Product":{"code":"SG19M","label":"APARs - z\/OS environment"},"Platform":[{"code":"PF054","label":"z Systems"}],"Line of Business":{"code":"","label":""}}]

Document Information

Modified date: