PH23079: ABEND0C4 OCCURRED IF THERE IS AN INSENSITIVE SEGMENT.

A fix is available

Subscribe

You can track all active APARs for this component.

 

APAR status

  • Closed as program error.

Error description

  • If all segments were not unloaded as sensitive, the HP Load
    could abend with ABEND0C4.
    

Local fix

Problem summary

  • ****************************************************************
    * USERS AFFECTED: All users of IBM IMS High Performance Load   *
    *                 for z/OS Version 2 Release 1 (FMID=H1IM210). *
    ****************************************************************
    * PROBLEM DESCRIPTION: If all segments were not unloaded as    *
    *                      sensitive, the HP Load could abend with *
    *                      ABEND0C4.                               *
    ****************************************************************
    * RECOMMENDATION: Apply the maintenance for this APAR.         *
    ****************************************************************
    HP Load could be ABEND0C4 if a DBD change was made with the
    segment type deleted.
    When counting the number of unloaded segments, HP Load will
    refer beyond the segment table if the deleted segment type is
    not found in the internal segment table.
    

Problem conclusion

  • The HP Load has been modified to reference the internal segment
    table correctly.
    

Temporary fix

Comments

APAR Information

  • APAR number

    PH23079

  • Reported component name

    IMS HP LOAD

  • Reported component ID

    5655E0700

  • Reported release

    210

  • Status

    CLOSED PER

  • PE

    NoPE

  • HIPER

    NoHIPER

  • Special Attention

    NoSpecatt / Xsystem

  • Submitted date

    2020-03-09

  • Closed date

    2020-03-23

  • Last modified date

    2022-09-08

  • APAR is sysrouted FROM one or more of the following:

  • APAR is sysrouted TO one or more of the following:

    UI68557

Modules/Macros

  • HPSRHDL2 HPSRHDL3 HPSRHDL4 HPSRHDL5 HPSRHDL7 HPSRHDL8 HPSRHDL9
    HPSRHDLA HPSRHDLB HPSRHSL2 HPSRHSL3 HPSRHSL4 HPSRHSL5 HPSRHSL7
    HPSRHSL8 HPSRHSL9 HPSRHSLA HPSRHSLB HPSRRLD2 HPSRRLD3 HPSRRLD4
    HPSRRLD5 HPSRRLD7 HPSRRLD8 HPSRRLD9 HPSRRLDA HPSRRLDB
    

Fix information

  • Fixed component name

    IMS HP LOAD

  • Fixed component ID

    5655E0700

Applicable component levels

  • R210 PSY UI68557

       UP20/03/25 P F003

Fix is available

  • Select the PTF appropriate for your component level. You will be required to sign in. Distribution on physical media is not available in all countries.

[{"Business Unit":{"code":"BU048","label":"IBM Software"},"Product":{"code":"SSCX89F","label":"IMS Tools"},"Platform":[{"code":"PF025","label":"Platform Independent"}],"Version":"2.1.0"}]

Document Information

Modified date:
08 September 2022