IBM Support

PH20462: 837 2400 REF LINE ITEM CONTROL NUMBER PASSES COMPLIANCE CHECK WHEN THERE ARE MULTIPLE 2400 REF*6 WITHIN A CLM01

Subscribe to this APAR

By subscribing, you receive periodic emails alerting you to the status of the APAR, along with a link to the fix after it becomes available. You can track this item individually or track all items by product.

Notify me when this APAR changes.

Notify me when an APAR for this component changes.

 

APAR status

  • Closed as program error.

Error description

  • An 837I transaction passes compliance when there are multiple
    2400 REF*6 within a CLM01 where the REF02 value is not unique.
    The TR3 requires the line item control number to be unique
    within the patient control number (CLM01).
    
    Within each 2300 Loop, all occurrences of 2400 REF*6R must
    have unique REF02 values. This applies to all 837s
    (professional, institutional, dental), but not the PACDR
    837's.
    

Local fix

  • ITXCQ - ITX00060156
    JK / JK
    Circumvention: None
    

Problem summary

  • Users affected:
    Transformation Extender Pack for Healthcare Payer HIPAA
    
    Problem Description:
    
    837 2400 REF Line Item Control Number passes compliance check
    when there are multiple 2400 REF*6R segments within a Claim
    where the REF02 value is not unique.
    
    Platforms affected:
    ALL
    

Problem conclusion

  • New XT type rules 59171,59172,59173 for unique REF*6R in 837s.
    
    They are disabled by default.
    
    hcsvu exit updated (rules.h) with changes to rule type 10 to
    support these new rules.
    
    Applies to:
    Healthcare Payer 9.0.2, 10.0
    
    Fixed in the next Service Pack and releases.
    
    To obtain the fix for this APAR:
    
    To see if the next service pack or product release is available,
     check the IBM Transformation Extender Release Notes page:
    http://www.ibm.com/support/docviews.wss?uid=swg27008337
    
    If the service pack or product release is available, download it
    from Fix Central:
    http://www.ibm.com/support/fixcentral/
    
    If the service pack or product release is not available and you
    require the APAR fix immediately, request a Limited Availability
    Interim Fix (LAIF) by openung a PMR:
    http://www.ibm.com/mysupport/
    
    Prior to version 9.0.0, IBM Transformation Extender was called
    IBM WebSphere Transformation Extender.
    

Temporary fix

Comments

APAR Information

  • APAR number

    PH20462

  • Reported component name

    TX HIPPA EDI

  • Reported component ID

    5724M6100

  • Reported release

    901

  • Status

    CLOSED PER

  • PE

    NoPE

  • HIPER

    NoHIPER

  • Special Attention

    NoSpecatt / Xsystem

  • Submitted date

    2019-12-18

  • Closed date

    2020-01-29

  • Last modified date

    2020-02-21

  • APAR is sysrouted FROM one or more of the following:

  • APAR is sysrouted TO one or more of the following:

Fix information

  • Fixed component name

    TX HIPPA EDI

  • Fixed component ID

    5724M6100

Applicable component levels

[{"Business Unit":{"code":"BU059","label":"IBM Software w\/o TPS"},"Product":{"code":"SSVSD8","label":"IBM Transformation Extender"},"Component":"","ARM Category":[],"Platform":[{"code":"PF025","label":"Platform Independent"}],"Version":"901","Edition":"","Line of Business":{"code":"LOB59","label":"Sustainability Software"}}]

Document Information

Modified date: