IJ23355: HTTPCONNTIMEOUT AND HTTPREADTIMEOUT VALUES ARE NOT BEING TAKEN INTO ACCOUNT.

Subscribe to this APAR

By subscribing, you receive periodic emails alerting you to the status of the APAR, along with a link to the fix after it becomes available. You can track this item individually or track all items by product.

Notify me when this APAR changes.

Notify me when an APAR for this component changes.

 

APAR status

  • Closed as program error.

Error description

  • Problem details:
    =================
    The issue is that the
    HTTPCONNTIMEOUT and HTTPREADTIMEOUT values are not being taken
    into account.
    
    The log shows the values for HTTPCONNTIMEOUT
    and HTTPREADTIMEOUT are being passed in correctly to
    psdi.iface.webservices.JAXWSClient, and are used to set
    "com.ibm.wsspi.webservices.Constants.RESPONSE_TIMEOUT_PROPERTY"
    and
    "com.ibm.wsspi.websvcs.Constants.CONNECTION_TIMEOUT_PROPERTY"
    in the dispatch.
    
    Application
    
    ===========
    Webservices
    
    steps
    =======
    1. Create a new
    Interaction based on the wsdl from the first instance
    for the
    Inventory app.
    
    2. Check the end point created by the
    interaction and set
    HTTPCONNTIMEOUT and HTTPREADTIMEOUT to
    1000.
    
    3. Go To -> Inventory -> select action -> External
    Services -> call the
    interaction: Query:
    ORGID='EAGLENA'
    
    Results/Problem
    ==================
    The
    response takes more than 1 second and it does not time
    out.
    
    Expected Results
    ================
    The read timeout should
    work fine
    
    
    Customer Product Version
    
    ========================
    Maximo 7.6.1.1
    

Local fix

  • "JAXWSClient-DUP0003.class" has been provided to the client and
    The readtimeout work fine with the latest class.
    

Problem summary

  • ****************************************************************
    * USERS AFFECTED:                                              *
    * MAXIMO                                                       *
    ****************************************************************
    * PROBLEM DESCRIPTION:                                         *
    * HTTPCONNTIMEOUT AND HTTPREADTIMEOUT VALUES ARE NOT BEING     *
    * TAKEN INTO ACCOUNT.                                          *
    ****************************************************************
    * RECOMMENDATION:                                              *
    ****************************************************************
    

Problem conclusion

  • The fix for this APAR is contained in the following maintenance
    package:
    	 | release\fix pack | Interim Fix for Release 7.6.1.2 Product
    

Temporary fix

Comments

APAR Information

  • APAR number

    IJ23355

  • Reported component name

    INTEGRATION

  • Reported component ID

    5724R46I1

  • Reported release

    761

  • Status

    CLOSED PER

  • PE

    NoPE

  • HIPER

    NoHIPER

  • Special Attention

    NoSpecatt / Xsystem

  • Submitted date

    2020-03-06

  • Closed date

    2020-03-12

  • Last modified date

    2020-03-12

  • APAR is sysrouted FROM one or more of the following:

  • APAR is sysrouted TO one or more of the following:

Fix information

  • Fixed component name

    INTEGRATION

  • Fixed component ID

    5724R46I1

Applicable component levels

[{"Business Unit":{"code":"BU059","label":"IBM Software w\/o TPS"},"Product":{"code":"SSLKT6","label":"IBM Maximo Asset Management"},"Component":"","ARM Category":[],"Platform":[{"code":"PF025","label":"Platform Independent"}],"Version":"761","Edition":"","Line of Business":{"code":"LOB59","label":"Sustainability Software"}}]

Document Information

Modified date:
12 March 2020