In async GLVM configuration with multiple networks, when a network fails, the LVs may get marked as stale.
Local fix
Problem summary
In async GLVM configuration with multiple networks, when a network fails, the LVs may get marked as stale.
Problem conclusion
GLVM code has been modified to not fail the good network.