IBM Support

Release of the QRadar 7.3.1 Patch 3 SFS (7.3.1.20180327211425)

Release Notes


Abstract

This technical note contains installation instructions, and a list of new features and resolved issues for the IBM Security QRadar 7.3.1 Patch 3 (7.3.1.20180327211425) SFS. These instructions are intended for administrators who use an SFS file to upgrade from QRadar 7.3.1 to QRadar 7.3.1 Patch 3.

Content

Upgrade information
QRadar 7.3.1 Patch 3 resolves 39 reported issues from users and administrators from previous QRadar versions. This cumulative software update fixes known software issues in your QRadar deployment. QRadar software updates are installed by using an SFS file. The software update can update all appliances attached to the QRadar Console. If you have installed any of the following QRadar versions, install software update 7.3.1-QRADAR-QRSIEM-20180327211425 to upgrade to QRadar 7.3.1 Patch 3:


Current QRadar VersionUpgrades to QRadar 7.3.1 Patch 3?
QRadar 7.2.8 (any patch version)No, see QRadar 7.3.1 Patch 3 ISO Release Notes.
QRadar 7.3.0 (any patch version)Yes. Administrators can apply this SFS file to update to 7.3.1 Patch 3.
QRadar 7.3.1Yes. Administrators can apply this SFS file to update to 7.3.1 Patch 3.


The 7.3.1-QRADAR-QRSIEM-20180327211425 SFS file can upgrade QRadar 7.3.0 to QRadar 7.3.1 Patch 3. However, this document does not cover all the installation messages and requirements, such as changes to appliance memory requirements or browser requirements for QRadar. To review any additional requirements, see the QRadar Upgrade Guide.

Before you begin
Ensure that you take the following precautions:

  • Back up your data before you begin any software upgrade. For more information about backup and recovery, see the QRadar Administration Guide.
  • To avoid access errors in your log file, close all open QRadar sessions.
  • The software update for QRadar cannot be installed on a managed host that is at a different software version from the Console. All appliances in the deployment must be at the same software revision to update the entire deployment.
  • Verify that all changes are deployed on your appliances. The update cannot install on appliances that have changes that are not deployed.
  • If this is a new installation, review the instructions in the QRadar Installation Guide.


Installing the QRadar 7.3.1 Patch 3 Software Update
These instructions guide you through the process of upgrading an existing QRadar version from 7.3.1 to QRadar 7.3.1 Patch 3. For information about updating appliances in parallel, see: QRadar: How to Update Appliances in Parallel.


Procedure

  1. Download the software update to install QRadar 7.3.1 Patch 3 from the IBM Fix Central website: ibm.biz/BdZvhh
  2. Use SSH to log in to your Console as the root user.
  3. To verify that you have enough space (3 GB) in /storetmp for the QRadar Console, type:
    df -h /tmp /storetmp /store/transient | tee diskchecks.txt
    • Best directory option: /storetmp
      It is available on all appliance types, is not cleaned up if you need to postpone your update, and is available on all appliance types at all versions. In QRadar 7.3.0 versions /storetmp is a symlink to the /storetmp partition.
    • 2nd best directory option: /tmp
      This directory is available on all appliances, but in the 7.3.0 versions it is significantly smaller. Moving a file to this directory can cause services to stop. If you leave a file in /tmp for 10 days without completing the SFS update, it might get cleaned up by Red Hat's tmpwatch cron job.
    • 3rd best option: /store/transient
      The store/transient directory was introduced in QRadar 7.2.1 and is allocated 10% of the overall /store directory. However, this directory does not exist on all appliances, such as QFlow or QRadar Network Insights and might not be an actual partition on all appliances.


      If the disk check command fails, retype the quotation marks from your terminal, and then re-run the command. This command returns the details to both the command window and to a file on the Console named diskchecks.txt. Review this file to ensure that all appliances have at minimum 3 GB of space available in a directory to copy the SFS before attempting to move the file to a managed host. If required, free up disk space on any host that fails to have less that 3 GB available.


      Note:
      In QRadar 7.3.0 and later, an update to directory structure for STIG compliant directories reduces the size of several partitions. This can impact moving large files to QRadar.

  4. To create the /media/updates directory, type the following command: mkdir -p /media/updates
  5. Use SCP to copy the files to the /storetmp directory on the QRadar Console or a location with 3 GB of disk space.
  6. Change to the directory where you copied the software update file. For example, cd /storetmp
  7. To mount the software update file to the /media/updates directory, type the following command:
    mount -o loop -t squashfs /storetmp/731_QRadar_patchupdate-7.3.1.20180202182152.sfs /media/updates
  8. To run the software update installer, type the following command: /media/updates/installer
    Note: The first time that you run the software update, there might be a delay before the installation menu displays.
  9. Using the software update installer, select all.
    • The all option updates the software on all appliances in the following order:


      1. Console.
      2. No order required for remaining appliances. All remaining appliances can be updated in any order you require.

    • If you do not select the all option, you must select your Console appliance.

      As of QRadar 7.2.6 Patch 4 and later, you are only provided the option to update all or update the Console appliance. Managed hosts are not displayed in the installation menu to ensure that the Console is updated first. After the Console is updated, a list of managed hosts that can be updated is displayed in the installation menu. This change was made starting with QRadar 7.2.6 Patch 4 to ensure that the Console appliance is always updated before managed hosts, to prevent upgrade issues.

      If you want to update systems in series, you can update the Console first, then copy the software update to all other appliances and run the installer individually on each managed host. The Console must be updated before you can run the installer on managed hosts. When updating in parallel, there is no order required in how you update appliances after the Console is updated.

      If your Secure Shell (SSH) session is disconnected while the upgrade is in progress, the upgrade continues. When you reopen your SSH session and re-run the installer, the software update installation resumes.



Installation wrap-up
  1. After the update completes and you have exited the installer, type the following command: umount /media/updates
  2. Clear your browser cache before logging in to the Console.

    Results
    A summary of the software update installation advises you of any managed host that were not updated. If the software update fails to update a managed host, you can copy the software update to the host and run the installation locally.

    After all hosts are updated, you can send an email to your team to inform them that they will need to clear their browser cache before logging in to the QRadar SIEM interface.



Known and Resolved Issues


Some APAR links in the following table might take 24 hours to display properly after a software release is posted to IBM Fix Central.

Resolved issues in QRadar 7.3.1 Patch 3
Product Component Number Description
QRADAR INCIDENT FORENSICSSECURITY BULLETINCVE-2018-1418IBM QRadar Incident Forensics, as found in IBM QRadar SIEM, is vulnerable to an authentication bypass leading to remote command injection
QRADARSECURITY BULLETINCVE-2017-1724IBM QRadar SIEM is vulnerable to cross-site scripting
QRADAR INCIDENT FORENSICSSECURITY BULLETINCVE-2017-1723IBM QRadar Incident Forensics, as used in IBM QRadar SIEM, is vulnerable to authenticated path traversal
QRADARSECURITY BULLETINCVE-2017-1722IBM QRadar SIEM is vulnerable to SQL Injection
QRADAR INCIDENT FORENSICSSECURITY BULLETINCVE-2017-1721IBM QRadar Incident Forensics, as found in IBM QRadar SIEM, is vulnerable to remote code execution
QRADARSECURITY BULLETINCVE-2014-3576IBM QRadar SIEM contains vulnerable components and libraries
QRADARSECURITY BULLETINCVE-2011-4314IBM QRadar SIEM contains vulnerable components and libraries
QRADARSECURITY BULLETINCVE-2016-4970IBM QRadar SIEM contains vulnerable components and libraries
QRADARSECURITY BULLETINCVE-2015-5262IBM QRadar SIEM contains vulnerable components and libraries
QRADARSECURITY BULLETINCVE-2016-3092QRadar SIEM contains vulnerable components
QRADARSECURITY BULLETINCVE-2015-0250IBM QRadar SIEM contains vulnerable components
QRADARSECURITY BULLETINCVE-2016-9878IBM QRadar SIEM contains vulnerable components and libraries
QRADARSECURITY BULLETINCVE-2015-5262IBM QRadar SIEM contains vulnerable components and libraries
QRADARSECURITY BULLETINCVE-2017-1624IBM QRadar SIEM is vulnerable to incorrect permission assignment.
QRADARSECURITY BULLETINCVE-2017-1733IBM QRadar SIEM is vulnerable to information exposure through log files.
QRADARSECURITY BULLETINCVE-2017-12163Open Source Samba as used in IBM QRadar SIEM is vulnerable to information exposure.
QRADARSECURITY BULLETINCVE-2017-12629Open Source Apache Solr as used in IBM QRadar Incident Forensics is vulnerable to arbitrary code execution.
QRADARSEARCHIJ00857RESOURCE LEAK IN ARIEL CAN CAUSE QUERY PROCESSING TO STOP
QRADARREPORTSIV98739CHANGES MADE TO CUSTOM COLUMN DEFINITION LAYOUT IN LOG/FLOW ACTIVITY DO NOT PERSIST
QRADARSEARCHIV95449USING THE 'UPDATE' BUTTON ON A LOG ACTIVITY SEARCH PAGE THE DAY OF A DST (TIME) CHANGE MOVES THE START/END TIME ONE HOUR
QRADARSEARCHIV91635QUICK SEARCHES CANNOT BE REMOVED FROM THE QUICK SEARCH LIST
QRADARREPORTSIJ01012A REPORT RUN AGAINST A LOG ACTIVITY SAVED AQL SEARCH MAY BE GENERATED WITH AN ERROR.
QRADARREPORTSIJ00416LOG AND NETWORK ACTIVITY EXPORTS TO CSV DISPLAY INCORRECT COLUMN NAMES
QRADARREPORTSIJ00066TABLE REPORTS USING ACCUMULATED AQL DATA DISPLAY INCORRECT COLUMNS
QRADAREVENT DATAIJ03379EVENT DATA PROCESSED INTO SPILLOVER CAN SOMETIMES FAIL TO PARSE WHEN PROCESSED BY THE REGULAR QRADAR PIPELINE
QRADARAPI SEARCHIV98260API SEARCHES USING A COMPLETED ARIEL SEARCH CAN SOMETIMES RETURN WITH AN ERROR 500
QRADARREPORTSIJ03534SOME GLOBAL VIEWS NOT WORKING AS EXPECTED AFTER UPGRADING TO 7.3.1.X CAUSING NO DATA IN DASHBOARDS AND FAILED REPORTS
QRADARKERNELIJ00141DISK MAINTENANCE DELETES /STORE/ARIEL/FLOWS (RECORDS AND PAYLOADS) DIRECTORY ON DATANODES THAT RECEIVE EVENTS ONLY
QRADAR NETWORK INSIGHTSFLOW COLLECTIONIJ04056PORT BASED APPLICATION MAPPINGS ARE IGNORED WHEN USING QRADAR NETWORK INSIGHTS
QRADAR NETWORK INSIGHTSFORENSICSIJ00952QNI DECAPPER STOPPED BECAUSE OF A RHEL OUT OF MEMORY FUNCTION
QRADARHIGH AVAILABILITYIJ03342NETFLOW TRAFFIC CONTAINING SUPERFLOWS CAN SOMETIMES REPORT INCORRECT FIRST/LAST PACKET TIME
QRADARAPPLICATION INSTALLIJ02076QRADAR APPS INSTALLED ON AN APPNODE CAN SOMETIMES FAIL TO LOAD/OPEN/INSTALL
QRADARAPPLICATION INSTALLIJ01144APPS THAT TAKE LONGER THAN 8 MINUTES TO INSTALL MAY BE STOPPED BY THE MARATHON HEALTH CHECK REGARDLESS OF THE APP HEALTH CHECK
QRADARAPPLICATION INSTALLIJ00207QRADAR APPLICATIONS CAN FAIL TO INSTALL OR UPGRADE WHEN THERE IS INSUFFICIENT FREE SPACE IN /TMP
QRADARUSER INTERFACEIV99511LOG SOURCE GROUP WINDOW CAN SOMETIMES FAIL TO LOAD WHEN GREATER THAN 1000 LOG SOURCES EXIST IN A GROUP
QRADARINSTALL/UPGRADEIJ03213QRADAR SYSTEMS BUILT AT 7.2.2.-7.4 CAN FAIL TO UPGRADE TO 7.3.1.X WITH A 'TA_DSM_INFO' VIOLATES FOREIGN KEY ERROR
QRADARDSM EDITORIJ00975A SESSION LEAK IN TOMCAT MAY OCCUR WHEN USING THE DSM EDITOR
QRADARHIGH AVAILABILITYIV94966XX48 HIGH AVAILABILITY APPLIANCES CAN BECOME UNRESPONSIVE DURING DRBD SYNCRONIZATION WHEN CONFIGURED WITH CROSSOVER
QRADARHIGH AVAILABILITYIJ03669UPGRADE TO QRADAR 7.3.X CAN FAIL ON HIGH AVAILABILITY (HA) SYSTEMS WITH 'ERROR EXECUTING 30-CHECKPARTITIONS.SH'
QRADARINSTALL/UPGRADEIJ03410QRADAR PATCH PRETEST CAN FAIL WHEN A DEPLOYMENT HAS MORE THAN NINE (9) NAT IDS
QRADARINSTALL/UPGRADEIJ02095VIS CAN FAIL TO START DURING UPGRADE TO QRADAR 7.3.0.X
QRADARINSTALL/UPGRADEIJ01522QRADAR UPGRADE FROM 7.2.8.X TO 7.3.0.X CAN SOMETIMES FAIL ON APPLIANCES WITH BONDED INTERFACES
QRADARINSTALL/UPGRADEIJ01120FACTORY REINSTALL FAILS ON QRADAR APPLIANCES THAT HAVE BEEN UPGRADED FROM 7.2.8 TO 7.3.0
QRADARINSTALL/UPGRADEIJ00999UPGRADING TO QRADAR 7.3.0 MAY LEAD TO A 4GB ISO AND OTHER FILES IN /STORETMP
QRADARINSTALL/UPGRADEIJ00902STATIC ROUTES CONFIGURED IN QRADAR 7.2.8 ARE REMOVED DURING AN UPGRADE TO 7.3.0
QRADARINSTALL/UPGRADEIJ00882AFTER A 7.3.0 UPGRADE, SERVICES MAY FAIL TO START ON THE APPLIANCE AFTER A REBOOT
QRADARLICENSINGIV99772'THE NUMBER OF CONFIGURED LOG SOURCES IS APPROACHING OR HAS REACHED THE LICENSE LIMIT' SYSTEM EVENTS
QRADARLICENSINGIV97442'THE EPS OR FPM LICENSE POOL IS OVER-ALLOCATED. PLEASE CONTACT YOUR ADMINISTRATOR' MESSAGE ON LOG/NETWORK ACTIVITY TAB
QRADARUSER INTERFACEIJ01488QRADAR'S TOMCAT PROCESS CAN RUN OUT OF AVAILABLE FILE HANDLES CAUSING USER INTERFACE STABILITY/FUNCTIONALITY ISSUES
QRADARDATABASEIV85442THE X-FORCE SCASERVER PROCESS CAN FAIL TO START DUE TO DATABASE FILE CORRUPTION AFTER AN UPDATE
QRADAR VULNERABILITY MANAGERSCAN POLICYIV98247CLICKING 'SAVE' AFTER EDITING A SCAN POLICY CAN APPEAR TO HANG AND NOT SAVE SUCCESSFULLY
QRADAR VULNERABILITY MANAGERREPORTSIV95105REPORTS CREATED FROM VULNERABILITY SCAN PROFILES CAN SOMETIMES BE BLANK
QRADAR VULNERABILITY MANAGERINSTALL/UPGRADEIJ04398PATCH/UPGRADE TO QRADAR 7.3.1 PATCH 2 CAN HANG FOR AN EXTENDED PERIOD OF TIME (HOURS) WITH "VULN_MAP_ASSET_MV DOES NOT EXIST"
QRADAR VULNERABILITY MANAGERSCAN PROFILEIJ00368SAVING A SCAN PROFILE CAN TAKE LONGER THAN EXPECTED
QRADARAPIIV98655REFERENCE SETS THAT CONTAIN LARGE DATASETS THAT ARE LOADED VIA THE API CAN SOMETIMES CAUSE UI INSTABILITY/INACCESSABILITY
QRADARUSER INTERFACEIV98452EMAIL RESPONSE USING CUSTOM EMAIL TEMPLATE DISPLAYS A TEMPLATE STRING CODE INSTEAD OF 'N/A' FOR NULL CUSTOM PROPERTIES
QRADARCUSTOM EVENT PROPERTIESIJ02479CUSTOM EVENT PROPERTIES ASSIGNED TO A LOG SOURCE ARE NOT VISIBLE IN SEARCH FILTER FOR NON-ADMIN USER






Where do I find more information?



[{"Product":{"code":"SSBQAC","label":"IBM Security QRadar SIEM"},"Business Unit":{"code":"BU059","label":"IBM Software w\/o TPS"},"Component":"Release Notes","Platform":[{"code":"PF016","label":"Linux"}],"Version":"7.3.1","Edition":"All Editions","Line of Business":{"code":"LOB24","label":"Security Software"}}]

Document Information

Modified date:
17 June 2018

UID

swg27050917