IBM Support

Running Test Manager Suite fails with RT master: fatal user initialization error

Troubleshooting


Problem

Running Test Manager™ Suite produces the errors: RT master: fatal user initialization error. RT agent: Attached logfile directory non-empty prior to start of run.

Cause

The remote system has a directory used by the Test Manager RT agent process that contained files from a previous run. The directory is normally automatically cleaned upon the completion of a run. This problem can happen if a previous run was aborted or unforeseen application shutdown occurred.

Resolving The Problem

Go to the remote system and delete the following directory:

C:\Documents And Settings\<Username>\Local Settings\Temp\rtagent_#

The rtagent folder typically would be something like rtagent_0 or rtagent_1

The remedy is to delete this folder.