Error description

  • D-type APAR raised to cover change to CICS SFR copybooks in whic
    h EXEC CICS statrements are no longer pre-translated.
    

Local fix

Problem summary

  • ****************************************************************
    * USERS AFFECTED: All CICS SFR users.                          *
    ****************************************************************
    * PROBLEM DESCRIPTION: This PTF changes the way that EXEC      *
    *                      CICS statements are handled in CICS SFR *
    *                      source copybooks.                       *
    ****************************************************************
    * RECOMMENDATION:                                              *
    ****************************************************************
    All CICS Service Flow Runtime source copybooks which contain
    EXEC CICS statements are now supplied in non-translated form.
    

Problem conclusion

  • Translated strings for EXEC CICS statements have now been
    removed from all CICS Service Flow Runtime source copybooks,
    meaning customers will now have to use the integrated compiler
    when processing CICS Service Flow Runtime modules.
    ::::::::::::::::::::::::::::::::::::::::::::::::::::::::::::::::
    The CICS Service Flow Runtime Version 3 Release 1 User's Guide
    (SC34589906) will be updated as follows:
    
    In Chapter 10, "Problem Determination", on page 216 immediately
    following the end of the section entitled "CICS Service Flow
    Runtime additional error messages" (which started on page 212),
    insert the following section:
    
    ::::::::::::::::::::::::::::::::::::::::::::::::::::::::::::::::
    Applying APARs
    
    When you need to apply maintenance or fixes to the runtime
    environment, use the following process.
    
    Maintenance is applied using the JCL batch job called
    DFHMAINA. The JCL is very similar to the DFHMAINJ post-
    installation job, in that it contains a subset of the
    parameters from DFHMAINJ. DFHMAINA invokes a REXX program
    called DFHMAINX, which looks in member DFHMAINZ for a list of
    the changed and new members that require maintenance as part of
    an APAR. DFHMAINZ is cumulative and will contain members which
    have been altered by previous APARs as well as those which are
    affected by this APAR.
    
    1. Edit the DFHMAINA JCL, supplying the same parameter values
       as you would for DFHMAINJ. The parameters that you need to
       edit are:
    
       JOB1
          Together with JOB2 and JOB3, JOB1 is used to create the
          JCL statements for the required jobs in the .SCIZSAMP
          library. Do not alter the number of + symbols at the
          beginning of the statement as it is used to substitute
          the jobname when DFHMAINJ runs.
    
       JOB2
          JCL JOB statement continued.
    
       JOB3
          JCL JOB statement continued.
    
       SHLQ your.smpe.install.hlq
          A 1-35 character length value that is the data set name
          high level qualifier of the CICS SFR SMP/E installation
          libraries. This value must match what you specified in the
          previous step for syshlq.
    
       QUAL your.runtime.library.hlq
          A 1-35 character length value that is the data set name
          high level qualifier of the runtime libraries. This value
          must match what you specified in the previous step for
          hlqual.
    
        MQ YES|NO
           Indicates if you require support for WebSphere MQSeries
           (WMQ). If you specify MQ YES, then you must also define
           a value for the HLQMQ parameter. You must specify this
           parameter if you want to use the Simulator program to
           verify your installation.
    
         HLQCICS your.cics.hlq
            A 1-35 character length value that is the high level
         qualifier of the CICS. libraries.
    
         HLQCOBOL your.cobol.hlq
            A 1-35 character length value that is the high level
            qualifier of the COBOL runtime libraries.
    
    
         HLQCEE your.language.environment.hlq
            A 1-35 character length value that is the high level
            qualifier of the Language Environment  runtime
            libraries.
    
         PREFIX your.prefix
            The JCL jobname is created as a combination of this
            and the name of the member that is customized.
            For example, if you specify  PREFIX CSFR, this would
            rename jobs in the runtime libraries with CSFR as the
            first four characters e.g. DFHMASET would become
            CSFRASET. If you do not specify a value for this
            parameter, the sample jobs will have the same names as
            the member names.
    
         HLQMQ your.mq.hlq
            A 1-35 character length value that is the high level
            qualifier of the WMQ runtime libraries.
    
            Note: This parameter is required if you specified MQ YES
    
         THE_QMGR qmgrname
            A 1-4 character length value that is the name of the WMQ
            manager that resources are defined to.
    
            Note: This parameter is required if you specified MQ YES
    
    2. Submit DFHMAINA. DFHMAINA invokes the REXX program DFHMAINX.
       This replaces the SCIZMAC and SCIZLOAD runtime libraries,
       copies the members listed in DFHMAINZ from the SMP/E SCIZSAMP
       library to the runtime SCIZSAMP library and customizes the
       members using the parameter values that you supplied in
       DFHMAINA.
    
    3. Check the output for a return code of 0. Each member that is
       in DFHMAINZ should have a "Customizing member" message
       associated with it in the output.
    
       You should also see the following messages in the //SYSTSPRT
       of the DFHMAINA job output:
    
       CICS SFR SCIZSAMP customization beginning
       CICS SFR SCIZSAMP customization completed successfully.
    
       If you get a return code other than 0, you should investigate
       the cause of the error and correct it before rerunning
       DFHMAINA.
    
    4. Perform any additional steps if outlined in the APAR
       documentation.
    

Temporary fix

Comments

APAR Information

  • APAR number

    PK23258

  • Reported component name

    SERVICE FLOW FE

  • Reported component ID

    5655M1502

  • Reported release

    200

  • Status

    CLOSED PER

  • PE

    NoPE

  • HIPER

    NoHIPER

  • Special Attention

    NoSpecatt

  • Submitted date

    2006-04-13

  • Closed date

    2006-08-09

  • Last modified date

    2006-09-05

  • APAR is sysrouted FROM one or more of the following:

  • APAR is sysrouted TO one or more of the following:

Modules/Macros

  •    DFHMADPL DFHMADPP DFHMAD02 DFHMAD03 DFHMAERQ
    DFHMAERR DFHMAF02 DFHMAF04 DFHMAG03 DFHMAINA DFHMAINX DFHMAINZ
    DFHMALFC DFHMALFD DFHMALFS DFHMALIN DFHMALNM DFHMALPT DFHMALSC
    DFHMALTS DFHMAL02 DFHMAL04 DFHMAL22 DFHMAL24 DFHMAMGR DFHMAN03
    DFHMAN05 DFHMAQ03 DFHMASTM DFHMASTP DFHMAVCL DFHMAVCP DFHMAXAA
    DFHMAXAC DFHMAXAI DFHMAXAJ DFHMAXAO DFHMAXCA DFHMAXCC DFHMAXCI
    DFHMAXCO DFHMAXCP DFHMAXCS DFHMAXEC DFHMAXEP DFHMAXFC DFHMAXFI
    DFHMAXFO DFHMAXIC DFHMAXIO DFHMAXJC DFHMAXLB DFHMAXLC DFHMAXLI
    DFHMAXLO DFHMAXNA DFHMAXNN DFHMAXNS DFHMAXOC DFHMAXPI DFHMAXSC
    DFHMAXTC DFHMAX5P
    

Publications Referenced
SC34589906    

Fix information

  • Fixed component name

    SERVICE FLOW FE

  • Fixed component ID

    5655M1502

Applicable component levels

  • R200 PSY UK17061

       UP06/08/15 P F608

Fix is available

  • Select the PTF appropriate for your component level. You will be required to sign in. Distribution on physical media is not available in all countries.

[{"Business Unit":{"code":"BU048","label":"IBM Software"},"Product":{"code":"SSC5SJS","label":"Service Flow Feature"},"Component":"","ARM Category":[],"Platform":[{"code":"PF025","label":"Platform Independent"}],"Version":"3.1","Edition":"","Line of Business":{"code":"","label":""}}]

Document Information

Modified date:
05 September 2006