IBM Support

PK20149: INCREMENTAL IMAGE COPY BATCH FUNCTION DOES NOT ALLOW A RECOVERY UNLESS A /DBR IS DONE.

Subscribe

You can track all active APARs for this component.

 

APAR status

  • Closed as program error.

Error description

  • While testing DRF Beta and Incremental Image Copy batch function
    - stop a database and take a batch image copy.
    - start the database, and enter online transactions which will
      update the database
    - /DBR the database without NOFEOV, which produces a SLDS
    containing the database updates.
    - start the database.
    - submit the batch DRF IIC job.
    
    - **  batch DRF job goes into a wait state and displays the
      following message -
     FRD6003I SYTUND   SYTUND    AUTHORIZED BY  PROD
    

Local fix

  • If a /DBR is done to the database, then the DRF batch job
    completes.
    

Problem summary

  • ****************************************************************
    * USERS AFFECTED: All IMS Version 8 users with IMS Database    *
    *                 Recovery Facility Version 3 Release 1        *
    *                 installed.                                   *
    ****************************************************************
    * PROBLEM DESCRIPTION: Databases and Areas must be stopped in  *
    *                      order to take a DRF incremental image   *
    *                      copy (OUTPUT(ICR)).                     *
    ****************************************************************
    * RECOMMENDATION: INSTALL CORRECTIVE SERVICE FOR APAR/PTF      *
    ****************************************************************
    DRF has been changed to take both batch and concurrent ICRs
    (incremental image copies).  If all the required logs are
    available, the image copy is registered to DBRC as batch and the
    RUNTIME is the current time.  If only a subset of the required
    logs are available, the image copy is registered as concurrent
    and the RUNTIME is the latest stoptime of all the log data sets
    used.  The STOPTIME of this image copy is the current time.
    

Problem conclusion

  •  AIDS: RIDS/DBRC RIDS/UTL DBRC UTL
      DEP: NONE
      GEN:
    
    *** END IMS KEYWORDS ***
    DRF has been changed with APAR PK21934 to take both batch and
    concurrent ICRs (incremental image copies).  If all the required
    logs are available image copy is registered to DBRC as batch and
    the RUNTIME is the current time.  If only a subset of the
    required logs are available image copy is registered concurrent
    and the RUNTIME is the latest stoptime of all the log data sets
    used.  The STOPTIME of this image copy is the current time.
    
    If there have been no changes since the last image copy, meaning
    that an image copy record with the same RUNTIME exists, DRF
    issues message FRD6022A with the reason IMAGE COPY ALREADY TAKEN
    
    Message 'FRD6003I dbname AUTHORIZED BY ssid' is issued when an
    ADD control statement is processed if any of the databases are
    authorized.  This is partly for information only. This message
    is no longer issued when OUTPUT(ICR) is specified.
    
    Incremental image copies to a specified time (or what would be
    called timestamp incremental image copy) are not allowed. The
    RCVTIME parameter on the START control statement is not allowed
    when OUTPUT(ICR) is specified.  Error message FRD6124A INVALID
    DATA ENCOUNTERED.  KEYWORD: RCVTIME   RSN=SPECIFIC VALUE OF
    RCVTIME IS NOT ALLOWED FOR AN INCREMENTAL IMAGE COPY is issued
    and the job fails.  An image copy can be created as part of the
    normal recovery process, but an incremental image copy is not
    designed for timestamp image copies.
    
    DRF has also been changed to call auxilliary utilities with the
    correct list of DBDSs and areas to be processed.  Only those
    that can be recovered are passed.
    
    ----
    The following changes are made to the IMS Database Recovery
    Facility for z/OS User's Guide and Reference Version 3 Release 1
    manual number SC18-9407-00.
    
    Message FRD6022A adds a new reason:
    IMAGE COPY ALREADY TAKEN
        OUTPUT(ICR) option was specified, however there have been
        no changes since the last incremental image copy was
        taken.
    
    The System action for this reason is:
        This is not an error situation but an informational
        message.  No action is required.
    
    Message FRD6124A adds a new reason:
    SPECIFIC VALUE OF RCVTIME IS NOT ALLOWED FOR AN INCREMENTAL
    IMAGE COPY
        The OUTPUT(ICR) option was specified and RCVTIME was
        specified on the RECOVER START input control statement.
        This combination is not allowed, an incremental image copy
        cannot be taken to a specified time. If a timestamp recovery
        is desired along with an image copy, remove the OUTPUT(ICR)
        option.
    
    On page 72 under the IC option of the ADD control statement,
    there is a paragraph beginning with 'Only the batch image copy
    feature of HPIC is available ...' After this paragrpafh, add
    the following:
       When the OUTPUT(ICR) option is specified, the incremental
       image copy created may be batch or concurrent.  A concurrent
       image copy is created when only a subset of the required logs
       are available.  The RUNTIME used to register the image copy
       to DBRC is the latest stoptime of all the log data sets used
       as input.  It is not necessary to stop the database for an
       incremental image copy.
    

Temporary fix

Comments

APAR Information

  • APAR number

    PK20149

  • Reported component name

    IMS V8

  • Reported component ID

    5655C5600

  • Reported release

    800

  • Status

    CLOSED PER

  • PE

    NoPE

  • HIPER

    NoHIPER

  • Special Attention

    NoSpecatt

  • Submitted date

    2006-02-20

  • Closed date

    2006-06-28

  • Last modified date

    2007-02-13

  • APAR is sysrouted FROM one or more of the following:

  • APAR is sysrouted TO one or more of the following:

    PK25750 UK15868

Modules/Macros

  •    DFSRWCC  DFSRWCR  DSPRWV00 DSPRWV10 DSPRWV30
    DSPRWV40 DSPURVAR
    

Fix information

  • Fixed component name

    IMS V8

  • Fixed component ID

    5655C5600

Applicable component levels

  • R800 PSY UK15868

       UP06/06/30 P F606

[{"Business Unit":{"code":"BU048","label":"IBM Software"},"Product":{"code":"SSCVRBJ","label":"System Services"},"Component":"","ARM Category":[],"Platform":[{"code":"PF025","label":"Platform Independent"}],"Version":"800","Edition":"","Line of Business":{"code":"","label":""}}]

Document Information

Modified date: