A fix is available
APAR status
Closed as program error.
Error description
DB2 Object Compare completes with rc16 and INVALID TOKEN message when encountering a -1 ( minus one ) for PRIQTY or SECQTY value. Error messages appear similar to the following: . GOC2DTC - Unsuccessful completion Invalid token after PRIQTY keyword - expected integer value Error occured when parsing the following stmt : CREATE TABLESPACE TS59847 IN DB59847 USING STOGROUP SYSDEFLT PRIQTY -1 SECQTY -1 CCSID ASCII MAXROWS 255 Token number = 00010, Token =- . Problem appears in DB2 v8, where -1 is a valid value for either PRIQTY or SECQTY.
Local fix
Problem summary
**************************************************************** * USERS AFFECTED: Users of DB2 Administration Tool and * * users of DB2 Object Comparison Tool, * * who run in DB2 V8 environment and do * * "CREATE TS/IX where PQTY/SEQTY = -1", * * are affected. * **************************************************************** * PROBLEM DESCRIPTION: DB2 Object Comparison Tool completes * * with RC=16 and INVALID TOKEN message * * when encountering a -1 ( minus one ) * * for PRIQTY or SECQTY value. * * .* * * DB2 Administration Tool will encounter * * Parser error on CREATE TS/IX where * * PQTY/SEQTY = -1. * * Note: Validate, Interpret, Cloning * * commands for WSL. * * .* * * Problem appears in DB2 v8, where -1 is * * a valid value for either PRIQTY or * * SECQTY. * * .* * * Note: PK08475 is an IFREQ for PK07297. * **************************************************************** * RECOMMENDATION: * **************************************************************** See Problem Description.
Problem conclusion
Apply the fixes.
Temporary fix
Comments
APAR Information
APAR number
PK07297
Reported component name
DB2 OBJECT COMP
Reported component ID
5697G6400
Reported release
310
Status
CLOSED PER
PE
NoPE
HIPER
NoHIPER
Special Attention
NoSpecatt
Submitted date
2005-06-14
Closed date
2005-07-28
Last modified date
2005-09-02
APAR is sysrouted FROM one or more of the following:
APAR is sysrouted TO one or more of the following:
UK05807
Modules/Macros
GOC2DTC
Fix information
Fixed component name
DB2 OBJECT COMP
Fixed component ID
5697G6400
Applicable component levels
R310 PSY UK05807
UP05/08/05 P F508
Fix is available
Select the PTF appropriate for your component level. You will be required to sign in. Distribution on physical media is not available in all countries.
[{"Business Unit":{"code":"BU059","label":"IBM Software w\/o TPS"},"Product":{"code":"SSAUVH","label":"IBM Db2 Object Comparison Tool for z\/OS"},"Component":"","ARM Category":[],"Platform":[{"code":"PF025","label":"Platform Independent"}],"Version":"310","Edition":"","Line of Business":{"code":"LOB10","label":"Data and AI"}}]