PI62856: IBM TOOLS BASE SCRUB UTILITY, S0C7 CAUSED BY INCORRECT SCRUB JCLIN DUE TO A PARTICULAR SEQUENCE OF MAINTENANCE APPLIED

A fix is available

Subscribe

You can track all active APARs for this component.

 

APAR status

  • Closed as program error.

Error description

  • IBM Tools Base Scrub utility, S0C7 caused by incorrect Scrub
    JCLIN due to the sequence of maintenance applied after PTF
    UI24703 was applied and accepted.
    The following PTFs were erroneously shipped with an old version
    of the SCRUB utility JCLIN for FUDIMSPI: UI26004; UI26177;
    UI23653; UI28384; UI29629; UI30038; UI32070. These PTFs haves
    since been marked PE and replaced/superseded by PTFs UI35792 and
    UI36352 which this PTF will prereq.
    

Local fix

  • As a work around, until a PTF can be provided for this APAR, you
    can do the following to correct the 0C7 abend:
    1. If PTF UI24703 has been applied but not accepted then simply
    do an APPLY  REDO of PTF UI24703 to fix the 0C7.
    2. If PTF UI24703 has been accepted then you will need to
    restore a version of your Tools Base libraries before UI24703
    was accepted or applied or begin by installing a new copy of
    Tools Base product. Then APPLY all maintenance to bring you up
    to date.
    .
    NOTE: Make sure you install PTF UI24703 last; followed by any
    maintenance that PREREQs PTF UI24703 .
    

Problem summary

  • ****************************************************************
    * USERS AFFECTED: Users of IBM Tools Base Scrub utility V1.5   *
    ****************************************************************
    * PROBLEM DESCRIPTION: The following PTFs were erroneously     *
    *                      shipped with an old version of the      *
    *                      SCRUB utility JCLIN for FUDIMSPI:       *
    *                      UI26177; UI23653; UI28384; UI29629;     *
    *                      UI30038; UI32070                        *
    ****************************************************************
    * RECOMMENDATION:                                              *
    ****************************************************************
    IBM Tools Base Scrub utility, S0C7 caused by incorrect Scrub
    JCLIN due to the sequence of maintenance applied after PTF
    UI24703 was applied and accepted.
    

Problem conclusion

  • Reship the correct JCLIN for FUDIMSPI
    

Temporary fix

Comments

APAR Information

  • APAR number

    PI62856

  • Reported component name

    TOOLS BASE

  • Reported component ID

    5655V9300

  • Reported release

    150

  • Status

    CLOSED PER

  • PE

    NoPE

  • HIPER

    NoHIPER

  • Special Attention

    NoSpecatt / Xsystem

  • Submitted date

    2016-05-20

  • Closed date

    2016-05-26

  • Last modified date

    2016-06-02

  • APAR is sysrouted FROM one or more of the following:

  • APAR is sysrouted TO one or more of the following:

    UI38190

Modules/Macros

  •    FUDIMSPI HAHN150J
    

Fix information

  • Fixed component name

    TOOLS BASE

  • Fixed component ID

    5655V9300

Applicable component levels

  • R150 PSY UI38190

       UP16/05/31 P F605

Fix is available