A fix is available
APAR status
Closed as program error.
Error description
MSGFABG1150W is wrongly issued when running the Export utility to export data for HALDBs from a HISTORY data set.
Local fix
N/A
Problem summary
**************************************************************** * USERS AFFECTED: IBM IMS High Performance Pointer Checker for * * z/OS Version 3 Release 1 (FMID=HPC2310) * * users who run the Export Utility of DB * * Historical Data Analyzer (DBHDA). * **************************************************************** * PROBLEM DESCRIPTION: The Export Utility incorrectly exports * * none of the data of a HALDB or only a * * part of the data of a HALDB from the * * HISTORY data set. * **************************************************************** * RECOMMENDATION: Apply the maintenance for this APAR. * **************************************************************** When the following conditions are met, the Export Utility does not incorrectly export the data for a HALDB and issues MSGFABG1150W, or the Export Utility incorrectly exports only a part of the data of a HALDB: - More than one partition are defined in the HALDB. - Within the period when you try to export data from the HISTORY data set, the HISTORY data set contains the data only for several partitions of the HALDB.
Problem conclusion
The FABGXXPT module has been modified to fix the error.
Temporary fix
Comments
APAR Information
APAR number
PI57691
Reported component name
IMS POINTER CHE
Reported component ID
5655E0900
Reported release
310
Status
CLOSED PER
PE
NoPE
HIPER
NoHIPER
Special Attention
NoSpecatt / Xsystem
Submitted date
2016-02-21
Closed date
2016-03-08
Last modified date
2016-04-05
APAR is sysrouted FROM one or more of the following:
APAR is sysrouted TO one or more of the following:
UI35937
Modules/Macros
FABGXXPT
Fix information
Fixed component name
IMS POINTER CHE
Fixed component ID
5655E0900
Applicable component levels
R310 PSY UI35937
UP16/03/10 P F603
Fix is available
Select the PTF appropriate for your component level. You will be required to sign in. Distribution on physical media is not available in all countries.
[{"Business Unit":{"code":"BU054","label":"Systems w\/TPS"},"Product":{"code":"SG19M","label":"APARs - z\/OS environment"},"Component":"","ARM Category":[],"Platform":[{"code":"PF025","label":"Platform Independent"}],"Version":"3.1.0","Edition":"","Line of Business":{"code":"","label":""}},{"Business Unit":{"code":"BU048","label":"IBM Software"},"Product":{"code":"SSCX89G","label":"IMS HP Pointer Checker"},"Component":"","ARM Category":[],"Platform":[{"code":"PF025","label":"Platform Independent"}],"Version":"3.1.0","Edition":"","Line of Business":{"code":"","label":""}}]
Document Information
Modified date:
05 April 2016