A fix is available
APAR status
Closed as program error.
Error description
PRF V2R2 .BKO dataset exists after Job Cancel but no Backout is done on Job Restart
Local fix
The workaround is to verify whether or not the DFS036I message has been issued. If it has, delete or rename the .BKO file and restart the job as you normally would in that situation. Be aware that, in this situation, if backout is required, the backout will not be done. However, this situation is similar to a system outage. Restarting the abending job step will cause PRF to run the backout at that time.
Problem summary
**************************************************************** * USERS AFFECTED: Users of Program Restart Facility V2R2. * **************************************************************** * PROBLEM DESCRIPTION: PRF V2R2 .BKO dataset exists after * * Job Cancel but no Backout is done * * on Job Restart * **************************************************************** * RECOMMENDATION: * **************************************************************** PRF V2R2 .BKO dataset exists after Job Cancel but no Backout is done on Job Restart
Problem conclusion
Code has been added to correct this problem.
Temporary fix
Comments
APAR Information
APAR number
PI51028
Reported component name
IMS PGM RESTART
Reported component ID
5655E1400
Reported release
220
Status
CLOSED PER
PE
NoPE
HIPER
NoHIPER
Special Attention
NoSpecatt / Xsystem
Submitted date
2015-10-22
Closed date
2015-11-12
Last modified date
2015-12-03
APAR is sysrouted FROM one or more of the following:
APAR is sysrouted TO one or more of the following:
UI32914
Modules/Macros
IRTBKOC0
Fix information
Fixed component name
IMS PGM RESTART
Fixed component ID
5655E1400
Applicable component levels
R220 PSY UI32914
UP15/11/14 P F511
Fix is available
Select the PTF appropriate for your component level. You will be required to sign in. Distribution on physical media is not available in all countries.
[{"Business Unit":{"code":"BU054","label":"Systems w\/TPS"},"Product":{"code":"SG19M","label":"APARs - z\/OS environment"},"Component":"","ARM Category":[],"Platform":[{"code":"PF025","label":"Platform Independent"}],"Version":"220","Edition":"","Line of Business":{"code":"","label":""}},{"Business Unit":{"code":"BU058","label":"IBM Infrastructure w\/TPS"},"Product":{"code":"SSAVHR","label":"IMS Program Restart Facility for z\/OS"},"Component":"","ARM Category":[],"Platform":[{"code":"PF025","label":"Platform Independent"}],"Version":"220","Edition":"","Line of Business":{"code":"LOB35","label":"Mainframe SW"}}]
Document Information
Modified date: