Error description
During a RECOVERDM job run the following messages are received in the RECOVERDM job output when IMS is shutdown: IQC7003E - RC=0010 QCF CRITICAL ERROR IN MODULE IQCBTQCF IMS RC=00000010,RSN=ERROR IQC7017E PROCESSING HAS STOPPED DUE TO SYNCPOINT ERROR IQC4998I PIMS41CR RC=0000 AIBRC=0000 AIBRS=0000 These messages are expected in such case, when IMS is shutdown, but can differ depending on where IMS and the job completes. In this case the job output ends with RC=00 and states that messages have been reloaded when in fact they have not been reloaded. Adjustments will be made to have the job end with RC=08 in such case to notify the user the messages passed to IMS have not been committed.
Local fix
Problem summary
**************************************************************** * USERS AFFECTED: All users of QCF V3.1 * **************************************************************** * PROBLEM DESCRIPTION: IMS is shutdown during RECOVERDM run * * and the job output states that messages * * have been reloaded when, in fact, they * * have not. * **************************************************************** * RECOMMENDATION: * **************************************************************** During a RECOVERDM job run the following messages are received in the RECOVERDM job output when IMS is shutdown: IQC7003E - RC=0010 QCF CRITICAL ERROR IN MODULE IQCBTQCF IMS RC=00000010,RSN=ERROR IQC7017E PROCESSING HAS STOPPED DUE TO SYNCPOINT ERROR IQC4998I PIMS41CR RC=0000 AIBRC=0000 AIBRS=0000 These messages are expected in such case, when IMS is shutdown, but can differ depending on where IMS and the job completes. In this case the job output ends with RC=00 and states that messages have been reloaded when in fact they have not been reloaded. Adjustments will be made to have the job end with RC=08 in such case to notify the user the messages passed to IMS have not been committed.
Problem conclusion
When a Syncpoint Error occurs during the LOAD step of a RECOVERDM job or during a LOAD job, the user will be notified with 2 new messages. 1. IQC7020E No messages passed to IMS have been committed 2. IQC5516I No messages passed to IMS have been committed Also, if a Syncpoint Error does occur, the LOAD step will end with RC=08 instaed of RC=00 as it did before.
Temporary fix
Comments
APAR Information
APAR number
PI50674
Reported component name
IMS QUEUE CNTL
Reported component ID
5697E9900
Reported release
310
Status
CLOSED PER
PE
NoPE
HIPER
NoHIPER
Special Attention
NoSpecatt / Xsystem
Submitted date
2015-10-15
Closed date
2016-05-24
Last modified date
2016-07-04
APAR is sysrouted FROM one or more of the following:
APAR is sysrouted TO one or more of the following:
UI38118
Modules/Macros
IQCBTQCF IQCM1ENU IQCM2ENU IQCXCTRL
Fix information
Fixed component name
IMS QUEUE CNTL
Fixed component ID
5697E9900
Applicable component levels
R310 PSY UI38118
UP16/06/02 P F606
Fix is available
Select the PTF appropriate for your component level. You will be required to sign in. Distribution on physical media is not available in all countries.
[{"Business Unit":{"code":"BU054","label":"Systems w\/TPS"},"Product":{"code":"SG19M","label":"APARs - z\/OS environment"},"Component":"","ARM Category":[],"Platform":[{"code":"PF025","label":"Platform Independent"}],"Version":"3.1.0","Edition":"","Line of Business":{"code":"","label":""}},{"Business Unit":{"code":"BU048","label":"IBM Software"},"Product":{"code":"SSCX8A6","label":"IMS Queue Control Facility"},"Component":"","ARM Category":[],"Platform":[{"code":"PF025","label":"Platform Independent"}],"Version":"3.1.0","Edition":"","Line of Business":{"code":"","label":""}}]
Document Information
Modified date:
04 July 2016