A fix is available
APAR status
Closed as program error.
Error description
OAE failed with MSGFPX0342E, however it is not a real space shortage. The error appeared as: FPX0342E The maximum number of volumes for the Temporary ADS is 1, but the size of the extended ADS exceeds the total number of CIs available for the device. . This message was inadvertently issued when it shouldn't have been. Two additional issues addressed: 1. FPA Analyze function received ABEND0CB HFPA5FI0 at x'0AAA' because 1 UOW used more than 100,000 IOVF CIs. ABENDS0CB S0CB 2. Pointer errors were detected after running the SDEP SCAN/DELETE utilities twice against an ADS that had been immediatedly reloaded by FPA Reload function.
Local fix
Problem summary
**************************************************************** * USERS AFFECTED: All users of HPFPU Fast Path Advanced Tool * * (FPA), Fast Path Online Tools (FPO), and * * Hash Check support for IMS HP Image Copy * * in Fast Path Solution Pack Version 1 * * Release 3 (FMID: HAHQ130). * **************************************************************** * PROBLEM DESCRIPTION: 1. FPO Online Area Extender (OAE) * * issued FPX0342E message incorrectly. * * 2. FPA ANALYZE function and Hash Check * * support for IMS HP Image Copy abended * * with S0CB. * * 3. Pointer errors were detected in an * * ADS reloaded by FPA Reload function. * **************************************************************** * RECOMMENDATION: Apply the maintenance for this APAR. * **************************************************************** This APAR addresses the following problems: 1. OAE Original Expansion issues the DEVTYPE macro and retrieves the number of physical cylinders on the device from the word 2 of the DEVTYPE results, then loads this number to R15 with LH. When the volume has more than 65,520 cylinders, the value in R15 would be negative, which causes OAE to issue FPX0342E incorrectly. 2. FPA ANALYZE got abend S0CB in the module HFPA5FI0, and the Hash Check support for IMS HP Image Copy got abend S0CB in the module FABAHEXT, because the quotient exceeded the specified data size when 1 UOW used more than 100,000 IOVF CIs. 3. Pointer errors were detected after running the SDEP SCAN/DELETE utilities twice against an ADS that had been immediately reloaded by FPA Reload function.
Problem conclusion
1. OAE has been changed to: . load the number of cylinders to R15 with ICM. . issue a new message FPX0355I to indicate volume-related information of the original area data set and the temporary area data set. . retrieve the number of cylinders in full word format by using the INFO=DASD operand of the DEVTYPE macro when the number exceeds 65520. 2.FPA ANALYZE function and Hash Check support for IMS HP Image Copy have been changed to enlarge the work areas for very large value calculation. 3. FPA Reload function has been changed to update the next CI after the last CI which contains data, to contain a default segment.
Temporary fix
Comments
APAR Information
APAR number
PI49408
Reported component name
IMS FP SOLUTION
Reported component ID
5655W1400
Reported release
130
Status
CLOSED PER
PE
NoPE
HIPER
NoHIPER
Special Attention
NoSpecatt / Xsystem
Submitted date
2015-09-25
Closed date
2015-11-20
Last modified date
2015-12-02
APAR is sysrouted FROM one or more of the following:
APAR is sysrouted TO one or more of the following:
UI33159
Modules/Macros
FABAHEXT FPXBMBL0 FPXBPSZ0 FPXBPS40 FPXBRPT0 FPXBVOL0 FPXMSG00 FPXUITO0 HFPA5FI0 HFPA5P30 HFPA5RP0 HFPA5T30 HFPA5UW0 HFPKART0 HFPKSDL0 HFPKSEG0
Fix information
Fixed component name
IMS FP SOLUTION
Fixed component ID
5655W1400
Applicable component levels
R130 PSY UI33159
UP15/11/25 P F511
Fix is available
Select the PTF appropriate for your component level. You will be required to sign in. Distribution on physical media is not available in all countries.
[{"Business Unit":{"code":"BU054","label":"Systems w\/TPS"},"Product":{"code":"SG19M","label":"APARs - z\/OS environment"},"Component":"","ARM Category":[],"Platform":[{"code":"PF025","label":"Platform Independent"}],"Version":"130","Edition":"","Line of Business":{"code":"","label":""}},{"Business Unit":{"code":"BU048","label":"IBM Software"},"Product":{"code":"SSCV35A","label":"IMS Fast Path Solution Pack"},"Component":"","ARM Category":[],"Platform":[{"code":"PF025","label":"Platform Independent"}],"Version":"130","Edition":"","Line of Business":{"code":"","label":""}}]
Document Information
Modified date: