HC94397: PMG / BORING SPINDLE STOP : SPINDLE ROTATION ON NOT OUTPUTTED BETWEEN TWO POINTS.

Subscribe

You can track all active APARs for this component.

 

APAR status

  • Closed as program error.

Error description

  • PMG / BORING SPINDLE STOP : SINPDL ROTATION ON NOT OUTPUTTED
    BETWEEN TWO POINTS.
    .
    

Local fix

Problem summary

  •  INCIDENT DIAGNOSIS:
    SPINDLE ROTATION ON NOT OUTPUTTED BETWEEN TWO POINTS
    

Problem conclusion

  • THIS PROBLEM WILL BE FIXED ON
      CATIA VERSION 5 RELEASE 10 GA level.
    NOTE THAT THIS PROBLEM WILL ALSO BE FIXED ON V5R9SP01.
    NOTE THAT THIS PROBLEM WILL ALSO BE FIXED ON V5R8SP05.
    
     INCIDENT DIAGNOSIS:
    SPINDLE ROTATION ON NOT OUTPUTTED BETWEEN TWO POINTS
    
     TECHNICAL EXPLANATION FOR THE CORRECTION:
    For the machining of a boring spindle stop activity, we have
     to stop the spindle while machining a point.
    But the spindle was never switch on after the machining of the
    first point.
    So, the spindle was off when beginning to machine the other
    holes.
    
     ANSWER AND POSSIBLE BY-PASS:
    Now, the spindle is always swithed on after the machining of
     each point.(except the last point.)
    

Temporary fix

Comments

APAR Information

  • APAR number

    HC94397

  • Reported component name

    CATIA V5 NT_INT

  • Reported component ID

    569151000

  • Reported release

    508

  • Status

    CLOSED PER

  • PE

    NoPE

  • HIPER

    NoHIPER

  • Special Attention

    NoSpecatt

  • Submitted date

    2002-05-30

  • Closed date

    2002-06-17

  • Last modified date

    2003-06-10

  • APAR is sysrouted FROM one or more of the following:

  • APAR is sysrouted TO one or more of the following:

Modules/Macros

  •    FILE
    

Fix information

  • Fixed component name

    CATIA V5 NT_INT

  • Fixed component ID

    569151000

Applicable component levels

  • R508 PSN SP50805

       UP02/07/08 N 1000

  • R509 PSN SP50901

       UP02/07/26 N 1000

[{"Business Unit":{"code":"BU053","label":"Cloud & Data Platform"},"Product":{"code":"SSVJ2K","label":"CATIA V5"},"Component":"","ARM Category":[],"Platform":[{"code":"PF025","label":"Platform Independent"}],"Version":"508","Edition":"","Line of Business":{"code":"LOB10","label":"Data and AI"}}]

Document Information

Modified date:
10 June 2003