Error description
WORKBENCH:ASSEMBLY --------- FUNCTION: UPDATE THE ASSEMBLY -------- SCENARIO: -------- 3. FIX TOGETHER THE TWO PARTS 4. SET AN OFFSET BETWEEN THESE 2 PARTS 5. MOVE THE PART2 WITH THE COMPASS IN THE DIRECTION OF THE OFFSET 6. UPDATE THE ASSEMBLY => ERROR: THE PART1 MOVE WHILE UPDATING AND THE FIX IN SPACE CONSTRAINT CAN NOT BE UPDATED
Local fix
Problem summary
. INCIDENT DIAGNOSIS: A fixed Part in a Fix Together is moved when updating an assembly . TECHNICAL EXPLANATION FOR THE CORRECTION: when a fix constraint was put on a part of a fix together, the whole fix together was fixed, but the part could move in the fix together. Now, the part is fixed too. .
Problem conclusion
. THIS PROBLEM WILL BE FIXED ON CATIA VERSION 5 RELEASE 9 GA level. .
Temporary fix
Comments
APAR Information
APAR number
HC92261
Reported component name
CATIA V5 NT_INT
Reported component ID
569151000
Reported release
507
Status
CLOSED PER
PE
NoPE
HIPER
NoHIPER
Special Attention
NoSpecatt
Submitted date
2002-03-29
Closed date
2002-05-13
Last modified date
2002-05-13
APAR is sysrouted FROM one or more of the following:
APAR is sysrouted TO one or more of the following:
Modules/Macros
FILE
Fix information
Fixed component name
CATIA V5 NT_INT
Fixed component ID
569151000
Applicable component levels
R507 PSN
UP
R508 PSN
UP