APAR status
Closed as Permanent restriction.
Error description
SHEETMETAL - RECOGNIZE DOES NOT WORK ON PART WHICH HAS A STAMP . Scenario: 1. Open model in attachment called TMGY-56QLJG 2. Load sheetmetal workbench and select 'recognize' menu item 3. Select bottom surface that contains the halfsheer as the reference wall 4. Notice error: Cutout 1.===> topological operators ... internal error .
Local fix
Problem summary
SHEETMETAL - RECOGNIZE DOES NOT WORK ON PART WHICH HAS A STAMP
Problem conclusion
THIS PROBLEM IS PERMANENT RESTRICTION IN CATIA . BY-PASS: The stamp cannot be recognized and you have to delete the assemble.1 ,Body.2 and pocket.3(do not delete its skech) Edit (MB3/sketch.4 object) the sketch.4 and change support by Launch wall recognition selecting a face of wall1 and use this sketch with Surface stamp icon to recreate the stamp.
Temporary fix
Comments
APAR Information
APAR number
HC90594
Reported component name
CATIA V5 NT_INT
Reported component ID
569151000
Reported release
507
Status
CLOSED PRS
PE
NoPE
HIPER
NoHIPER
Special Attention
NoSpecatt
Submitted date
2002-02-14
Closed date
2002-03-12
Last modified date
2002-03-12
APAR is sysrouted FROM one or more of the following:
APAR is sysrouted TO one or more of the following:
Fix information
Applicable component levels
[{"Business Unit":{"code":"BU053","label":"Cloud & Data Platform"},"Product":{"code":"SSVJ2K","label":"CATIA V5"},"Component":"","ARM Category":[],"Platform":[{"code":"PF025","label":"Platform Independent"}],"Version":"507","Edition":"","Line of Business":{"code":"LOB10","label":"Data and AI"}}]
Document Information
Modified date:
12 March 2002