IBM Support

HC90010: ERROR WITHIN UNITS WHEN OPENING A CCD DRAWING DRAWN IN CM IN CATIA V5 DRAFTING.

Subscribe

You can track all active APARs for this component.

 

APAR status

  • Closed as suggestion for future release.

Error description

  • We get error within units when opening a CCD Drawing in
    Catia Drafting :
    CCD is drawn with units cm in a scale 1:40.
    Using option 'Drive geometry' when editing measure, units
    are 1:10 compared to the rest of the drawing.
    By Attaching Drafing view from drawing created from CCD,
    scale does not fit, size are 1:10 compared to the rest of
    the drawing.
    .
    Scenario:
    Catia Options.
    Change units within Parameters options folder 'Units':
    Units = cm
    .
    Drafting:
    1. Open CCD: mure.CCD
    2. Move View to Paper.
    3. Save drawing.
    4. Select an area of drawing to prepare a copy operation.
       Chose largest room in the middle of plant. (I want to
       copy a specific room of the plant)
    5. Copy selection.
    6. Start a new Draving Document.
    7. Add a view (Front View)
    8. Change View scale until 1:40 (same view size as original)
    9. Paste selection into Front View.
    10. Draw a Rectangle in connection to existing geometry and
        set on a Dimension.
    11.Edit Dimension and use 'Drive geometry'
    Result:
    Units does not fit
    12.Change View scale from 1:40 until 1:1
    13.Save Drawing.
    .
    Plant Design:
     1. Start a new Product.
     2. Work Bench: Plant Design
     3. Create Area.
     4. Edit Area Rectangel Object Definition:
    X length = 7205.5cm,
    Y length = 4291cm (largest room in the middle of plant)
     4. Attach drafting View from drawing just created. - - -
    units does not fit, is only 1:10 compared to Plant Design
    Area.
    It is a limitation issue related to the "DRAFTING" product.
    The limitation is that dimensional values can ONLY be
    displayed in MM or in INCH. In your case, current units are
    in CM but dimension value displays in MM.
    For example, when we double click on a dimension, the "
    Dimension Value - Drive Geometry" value displays in CM
    (ie: a dimension: 7175.99 displays as " drive Geom. value of
    717.599cm)
    We ask for the possibility to create a dimension which
    shares value in current units.
    

Local fix

Problem summary

Problem conclusion

Temporary fix

Comments

  • THIS APAR IS CONSIDERED AS A SUGGESTION FOR IMPROVEMENT FOR
    CATIA.
    PLEASE CONTACT YOUR SUPPORT DEPARTMENT IN ORDER TO OPEN A
    REQUIREMENT FORM.
    
     INCIDENT DIAGNOSIS:
    Dimensions do not follow the display unit available in Tools /
    Options. It is not possible to display a dimension in cm.
    
     JUSTIFICATION FOR DEVLOPMENT REQUEST:
    The users can customize the V5 session to get a display of the
    dimensions in CM. Nevertheless we intend to provide in V5R9 a
    default customization to get a display in cm and other units.
    
    Here is the detailed information:
    
    1) In V5R9 we will provide predefined display formats
       for dimensions, that enable to have a display in all
       types of units (cm, km, etc...).
    This solves the base problem of not being able to have
    dimensions in all units for users.
    2) By default, in the user interface, the display format will
       be set to one compatible with the units in Tools/Options
    3) The same behaviour can be achieved by administrators/users
       on V5 R7/R8 levels by customizing the CATDrwStandard file
       to define those display formats.
       As an example, here is what is needed to be added in
       the file to get a display in cm:
    BEGIN_NUMERICAL_DISPLAY
    NDName , DISTCM
    NDType , 1
    NDUnit , 1
    NDGlobFact , 10.000
    NDNulFac_1 , 1
    NDNulFac_2 , 2
    NDNulFac_3 , 1
    NDExise , 1
    NDSep1000 , 0
    NDFact_1 , 1.000000
    NDFact_2 , 0.000000
    NDFact_3 , 0.000000
    NDValPos_1 , 0.000000
    NDValPos_2 , 0.000000
    NDValPos_3 , 0.000000
    NDSepar_1 ,
    NDSepar_2 ,
    NDSepar_3 ,
    NDSepScl_1 , 1.000000
    NDSepScl_2 , 0.000000
    NDSepScl_3 , 0.000000
    NDSepPos_1 , 0.000000
    NDSepPos_2 , 0.000000
    NDSepPos_3 , 0.000000
    NDRestY , 0.000000
    NDFinZer , 1
    NDSepNum , 11
    NDTypFrac , 2
    NDSepDen , 2
    NDOperY , 0.500000
    NDNulOther , 1
    NDResScl , 1.000000
    NDFact , 1
    NDRestX , 0.500000
    END_NUMERICAL_DISPLAY
    
    But..
    Dimensions will NOT follow directly Tools/options, changing
    a dimension display unit will still be done by changing the
    display format in the dimension properties.
    
     ANSWER AND POSSIBLE BY-PASS:
    Users/administrators can define a display format in cm, by
    customzing the standard file. See Interactive Drafting
    Users's guide/Customizing/ManageStandards for more informati
    on.
    As an example here it what should be added to the file:
    BEGIN_NUMERICAL_DISPLAY
    NDName , DISTCM
    NDType , 1
    NDUnit , 1
    NDGlobFact , 10.000
    NDNulFac_1 , 1
    NDNulFac_2 , 2
    NDNulFac_3 , 1
    NDExise , 1
    NDSep1000 , 0
    NDFact_1 , 1.000000
    NDFact_2 , 0.000000
    NDFact_3 , 0.000000
    NDValPos_1 , 0.000000
    NDValPos_2 , 0.000000
    NDValPos_3 , 0.000000
    NDSepar_1 ,
    NDSepar_2 ,
    NDSepar_3 ,
    NDSepScl_1 , 1.000000
    NDSepScl_2 , 0.000000
    NDSepScl_3 , 0.000000
    NDSepPos_1 , 0.000000
    NDSepPos_2 , 0.000000
    NDSepPos_3 , 0.000000
    NDRestY , 0.000000
    NDFinZer , 1
    NDSepNum , 11
    NDTypFrac , 2
    NDSepDen , 2
    NDOperY , 0.500000
    NDNulOther , 1
    NDResScl , 1.000000
    NDFact , 1
    NDRestX , 0.500000
    END_NUMERICAL_DISPLAY
    

APAR Information

  • APAR number

    HC90010

  • Reported component name

    CATIA V5 NT_INT

  • Reported component ID

    569151000

  • Reported release

    507

  • Status

    CLOSED SUG

  • PE

    NoPE

  • HIPER

    NoHIPER

  • Special Attention

    NoSpecatt

  • Submitted date

    2002-01-31

  • Closed date

    2002-02-19

  • Last modified date

    2002-02-19

  • APAR is sysrouted FROM one or more of the following:

  • APAR is sysrouted TO one or more of the following:

Fix information

Applicable component levels

[{"Business Unit":{"code":"BU053","label":"Cloud & Data Platform"},"Product":{"code":"SSVJ2K","label":"CATIA V5"},"Component":"","ARM Category":[],"Platform":[{"code":"PF025","label":"Platform Independent"}],"Version":"507","Edition":"","Line of Business":{"code":"LOB10","label":"Data and AI"}}]

Document Information

Modified date:
19 February 2002