  • Closed as program error.

Error description

  • Start a V5 session:
    . File.Open the associated V4 model
    . Edit.Copy *MASTER
    . File.New Part
    . Edit.Paste Special as Specs
    . Update
      > EdgeFillet.1 ($FILL2): select a sharp edge
                                                                   .
    Comparing the erroneous edge in the V5 session, and the
    corresponding one for the V4 fillet, it appears that the
    selected edge in V5 is not the correct one.
    The same problem exists for Edgefillet.2.
    It is necessary to edit manually the definition of the
    Edgefillets to correct the fillet support edges.
    

Local fix

Problem summary

  • Error when retrieving edge when trying to build a fillet
    after a solid model is migrated to a V5 part.
    

Problem conclusion

  • THIS PROBLEM WILL BE FIXED ON
      CATIA VERSION 5 RELEASE 9 GA level.
                                                                   .
    The programming error is now corrected, and so the retrieved
    edge is correct, no message is issued.
    BUT for this particular model, the fillet propagation mode
    appaers as incorrect: minimal instead of tangent. The generated
    fillet is there not correct.
    This point is under study in the scope of a more important
    action which is not targeted for Release 9.
    Anyway, it is always recommended to migrate V54 solids into
    smart solids before migrating them.
    

Temporary fix

Comments

APAR Information

  • APAR number

    HC89604

  • Reported component name

    CATIA V5 NT_INT

  • Reported component ID

    569151000

  • Reported release

    507

  • Status

    CLOSED PER

  • PE

    NoPE

  • HIPER

    NoHIPER

  • Special Attention

    NoSpecatt

  • Submitted date

    2002-01-22

  • Closed date

    2002-04-18

  • Last modified date

    2002-04-18

  • APAR is sysrouted FROM one or more of the following:

  • APAR is sysrouted TO one or more of the following:

Modules/Macros

  •    FILE
    

Fix information

  • Fixed component name

    CATIA V5 NT_INT

  • Fixed component ID

    569151000

Applicable component levels

  • R507 PSN

       UP

  • R508 PSN

       UP

[{"Business Unit":{"code":"BU053","label":"Cloud & Data Platform"},"Product":{"code":"SSVJ2K","label":"CATIA V5"},"Component":"","ARM Category":[],"Platform":[{"code":"PF025","label":"Platform Independent"}],"Version":"507","Edition":"","Line of Business":{"code":"LOB10","label":"Data and AI"}}]