Error description
Executing an IGECAT on a specific IGES file results in an empty model. Type 110 (line) and 144 (trimmed surface) are not translated with following error messages: ITC34616 CAT02997 ITC34025 Tolerances have been changed with no correct result. This IGES file translates correctly on V5.
Local fix
Problem summary
Problem conclusion
Temporary fix
Comments
INCIDENT DIAGNOSIS: No elements in the model after an igecat process. CORRECT APPLICATION: The provided IGES file does not conform to the IGES Standard: All the floating point values in the Parameter Data records are specified using an 'e' (lowercase) to specifie the exponent part of value. According to the IGES Specification, an 'E' (uppercase) should be used to introduce exponent part in floating point values. See paragraph 2.2.2.2 of the IGES standard specification (ANSI US PRO/IPO-100-1996). The CATIA V4 IGES processor does not understand floating point value with an 'e' for the exponent. It silently translates the value to 0.0 and tries to continue processing. A By Pass to read this particular file is to change, at least in the Parameter Data Section, all 'e+' into 'E+' and all 'e-' into 'E-'.
APAR Information
APAR number
HC89212
Reported component name
CATIA FOR SGI
Reported component ID
562630000
Reported release
G22
Status
CLOSED USE
PE
NoPE
HIPER
NoHIPER
Special Attention
NoSpecatt
Submitted date
2002-01-09
Closed date
2002-08-30
Last modified date
2002-08-30
APAR is sysrouted FROM one or more of the following:
HC89210
APAR is sysrouted TO one or more of the following:
Fix information
Applicable component levels
[{"Business Unit":{"code":"BU053","label":"Cloud & Data Platform"},"Product":{"code":"SSLJ45","label":"CATIA-CADAM"},"Component":"","ARM Category":[],"Platform":[{"code":"PF025","label":"Platform Independent"}],"Version":"G22","Edition":"","Line of Business":{"code":"LOB10","label":"Data and AI"}}]
Document Information
Modified date:
30 August 2002