Error description
SCENARIO: - RegionSettings: Deutschland - Start CATIA - File, Open Part1_no_tbl_but_with_params.CATPart - Open (+) in tree: Parameters - see General, Number_2_decim, .... Date-parameters - sel icon Design Table, - sel OK ==> panel Choose construction file - sel test_geff.xls, Open, - Automatic Matching ? YES - sel fourth line of construction table to see parameter General the "ppp...kkk,,," as "ppp'spec.char'kkk,,, - sel button Edit table ==> Excel opens .xls file, - See the 5th line is CORRECT: ppp...kkk,,,ppp...kkk,,,x ==> ERROR, the construction table should look the same.
Local fix
Problem summary
DESIGN TABLE IN CATIA AND DESIGN TABLE IN EXCEL ARE DIFFERENT.
Problem conclusion
THIS PROBLEM IS PERMANENT RESTRICTION IN CATIA INCIDENT DIAGNOSIS: DESIGN TABLE IN CATIA AND DESIGN TABLE IN EXCEL ARE DIFFERENT. TECHNICAL EXPLANATION FOR THE RESTRICTION: This is a feature from excel, which replaces three points by a special character. (try to remove only one point from the three, this is not possible, you can only remove the three. Try to copy/Paste the three points in a text editor -> only one character is copied). BY-PASS: Don't use three following points
Temporary fix
Comments
APAR Information
APAR number
HC86667
Reported component name
CATIA V5 NT_INT
Reported component ID
569151000
Reported release
507
Status
CLOSED PRS
PE
NoPE
HIPER
NoHIPER
Special Attention
NoSpecatt
Submitted date
2001-10-24
Closed date
2001-11-07
Last modified date
2001-11-07
APAR is sysrouted FROM one or more of the following:
APAR is sysrouted TO one or more of the following:
Fix information
Applicable component levels
[{"Business Unit":{"code":"BU053","label":"Cloud & Data Platform"},"Product":{"code":"SSVJ2K","label":"CATIA V5"},"Component":"","ARM Category":[],"Platform":[{"code":"PF025","label":"Platform Independent"}],"Version":"507","Edition":"","Line of Business":{"code":"LOB10","label":"Data and AI"}}]
Document Information
Modified date:
07 November 2001