APAR status
Closed as suggestion for future release.
Error description
SHEETMETAL - CANNOT CREATE CUTOUT ON A USER FLANGE IN UNFOLDED VIEW, A TOPOLOGICAL ERROR 414414200 IS DISPLAYED. SCENARIO 1 - unfold the part 2 - select Sketch 4 and try to perform a cutout => Catia returns "414414200: Topological Operators: internal error."
Local fix
Problem summary
Problem conclusion
Temporary fix
Comments
THIS APAR IS CONSIDERED AS A SUGGESTION FOR IMPROVEMENT FOR CATIA. TECHNICAL EXPLANATION the cutout ( created in flat view) corresponds to an overlap ping area in folded view.This is not managed in sheet metal current release BY-PASS: reorder the user flange and create the cutout before the second flange by defining in work object user flange2 before cutout creation This issue will be solved in a next release
APAR Information
APAR number
HC85989
Reported component name
CATIA V5 NT_INT
Reported component ID
569151000
Reported release
507
Status
CLOSED SUG
PE
NoPE
HIPER
NoHIPER
Special Attention
NoSpecatt
Submitted date
2001-10-10
Closed date
2001-10-25
Last modified date
2001-10-25
APAR is sysrouted FROM one or more of the following:
APAR is sysrouted TO one or more of the following:
Fix information
Applicable component levels
[{"Business Unit":{"code":"BU053","label":"Cloud & Data Platform"},"Product":{"code":"SSVJ2K","label":"CATIA V5"},"Component":"","ARM Category":[],"Platform":[{"code":"PF025","label":"Platform Independent"}],"Version":"507","Edition":"","Line of Business":{"code":"LOB10","label":"Data and AI"}}]
Document Information
Modified date:
25 October 2001