Error description

  • SHEETMETAL - CANNOT CREATE CUTOUT ON A USER FLANGE IN UNFOLDED
    VIEW, A TOPOLOGICAL ERROR 414414200 IS DISPLAYED.
    
    SCENARIO
    
    1 - unfold the part
    2 - select Sketch 4 and try to perform a cutout
    => Catia returns "414414200: Topological Operators: internal
    error."
    

Local fix

Problem summary

Problem conclusion

Temporary fix

Comments

  • THIS APAR IS CONSIDERED AS A SUGGESTION FOR IMPROVEMENT FOR
    CATIA.
    
     TECHNICAL EXPLANATION
    the cutout ( created in flat view) corresponds to an overlap
    ping area in folded view.This is not managed in sheet metal
    current release
    
     BY-PASS:
    reorder the user flange and create the cutout before the second
    flange by defining in work object user flange2 before cutout
     creation
    This issue will be solved in a next release
    

APAR Information

  • APAR number

    HC85989

  • Reported component name

    CATIA V5 NT_INT

  • Reported component ID

    569151000

  • Reported release

    507

  • Status

    CLOSED SUG

  • PE

    NoPE

  • HIPER

    NoHIPER

  • Special Attention

    NoSpecatt

  • Submitted date

    2001-10-10

  • Closed date

    2001-10-25

  • Last modified date

    2001-10-25

  • APAR is sysrouted FROM one or more of the following:

  • APAR is sysrouted TO one or more of the following:

Fix information

Applicable component levels

[{"Business Unit":{"code":"BU053","label":"Cloud & Data Platform"},"Product":{"code":"SSVJ2K","label":"CATIA V5"},"Component":"","ARM Category":[],"Platform":[{"code":"PF025","label":"Platform Independent"}],"Version":"507","Edition":"","Line of Business":{"code":"LOB10","label":"Data and AI"}}]

Document Information

Modified date:
25 October 2001