APAR status
Closed as program error.
Error description
CATSEC does not work with the PRND type of flatfile for tees. Calculated weights are based upon the volume of the shape. We cannot leave out the fillets or we will not get the actual weights. HPs are modeled with fillets with no noticeable effect to model size or performance.
Local fix
Problem summary
INCIDENT DIAGNOSIS: CATSEC does not work for keyword PRND or PTAP (rounded corners, or rounded corners and tapered flanges). T with tapered flanges can not be created interactively. Radii or sloped flanges not visualized on screen. T-web side placement does not work with T-webs with rounded corners or tapered flanges.
Problem conclusion
THIS PROBLEM WILL BE FIXED ON CATIA VERSION 4 RELEASE 2.4 REFRESH 3 GA level (FREL424R3) TECHNICAL EXPLANATION FOR THE CORRECTION: Modification of the algorithm The following declarative needs to be setup to visualize all the section details : CATAEC.SETUP.STR.VISU_RAD=1; ANSWER AND POSSIBLE BY-PASS: The problem is corrected.
Temporary fix
Comments
APAR Information
APAR number
HC84677
Reported component name
CATIA FOR SGI
Reported component ID
562630000
Reported release
G24
Status
CLOSED PER
PE
NoPE
HIPER
NoHIPER
Special Attention
NoSpecatt
Submitted date
2001-09-11
Closed date
2002-04-05
Last modified date
2002-04-11
APAR is sysrouted FROM one or more of the following:
HC84675
APAR is sysrouted TO one or more of the following:
UB98312 UB98313 UB98317 UB98318
Modules/Macros
FILE
Fix information
Fixed component name
CATIA FOR SGI
Fixed component ID
562630000
Applicable component levels
RG24 PSY UB98318
UP02/04/11 I 1000
RH24 PSY
UP
[{"Business Unit":{"code":"BU053","label":"Cloud & Data Platform"},"Product":{"code":"SSLJ45","label":"CATIA-CADAM"},"Component":"","ARM Category":[],"Platform":[{"code":"PF025","label":"Platform Independent"}],"Version":"G24","Edition":"","Line of Business":{"code":"LOB10","label":"Data and AI"}}]
Document Information
Modified date:
11 April 2002