IBM Support

HC83703: NO SOLUTION FOR GRADIENT METHOD ( GENSTRESS )

Subscribe

You can track all active APARs for this component.

 

APAR status

  • Closed as unreproducible.

Error description

  • Abstract: EPMR: NSC : no solution for gradient method
    .
    Operating System:  Windows2000
    Product Group:  CATIA V5R6 Service Pack 3 or below on WinNT/2000
    Environment:
    HP Visualize W2000, 1GHz, 1Go RAM
    .
    Problem Description:
    create a cylinder in Part Design with Steel material;
    go in GPS workbench (static);
    apply a clamp on one of two circular face;
    apply a pressur on the other one (5e+006N_m2);
    double click on Static Solutions in the tree and choose
    Gradient Method with 3 iterations for example;
    compute;
    ask Von Mises view, there is nothing...
    .
    No material needed
    

Local fix

Problem summary

  •  INCIDENT DIAGNOSIS:
    NO SOLUTION FOR GRADIENT METHOD ( GENSTRESS )
    
    SCENARIO:
    Create a cylinder in Part Design with Steel Material
    Go to GPS Workbench (static)
    Apply a clamp on one of the two circular face
    Apply a pressure on the other one (5e+06N_m2)
    Doucle click on Static Solutions in the tree and choose
    Gradient Method with 3 iterations for example
    Compute
    Ask Von Mises view, there is nothing
    
     REASON:
    Problem solved on V5R7SP02
    

Problem conclusion

Temporary fix

Comments

  • THE PROBLEM WAS SUBMITTED ON :
        CATIA VERSION 5 RELEASE 6 SP3
    .
    THIS PROBLEM IS NOT REPRODUCIBLE ON :
        CATIA VERSION 5 RELEASE 7 SP2
    
     REASON:
    Problem solved on V5R7SP2
    

APAR Information

  • APAR number

    HC83703

  • Reported component name

    CATIA V5 NT_INT

  • Reported component ID

    569151000

  • Reported release

    506

  • Status

    CLOSED UR3

  • PE

    NoPE

  • HIPER

    NoHIPER

  • Special Attention

    NoSpecatt

  • Submitted date

    2001-08-14

  • Closed date

    2001-08-14

  • Last modified date

    2002-07-17

  • APAR is sysrouted FROM one or more of the following:

  • APAR is sysrouted TO one or more of the following:

Fix information

  • Fixed component name

    CATIA V5 NT_INT

  • Fixed component ID

    569151000

Applicable component levels

  • R506 PSN SP50606

       UP01/09/20 N 1000

[{"Business Unit":{"code":"BU053","label":"Cloud & Data Platform"},"Product":{"code":"SSVJ2K","label":"CATIA V5"},"Component":"","ARM Category":[],"Platform":[{"code":"PF025","label":"Platform Independent"}],"Version":"506","Edition":"","Line of Business":{"code":"LOB10","label":"Data and AI"}}]