APAR status
Closed as program error.
Error description
WORKBENCH: PRODUCT STRUCTURE ABSTRACT: IMPOSSIBLE TO SAVE SEARCH ORDER OPTION . SCENARIO: 1. OPEN CATIA V5 2. TOOLS / OPTIONS / GENERAL / DOCUMENT 3. IN LINK DOCUMENT LOCALIZATION , SELECT OTHER FOLDERS 4. CONFIGURE 5. DEFINE A PATH / ADD / OK / OK: 6. TOOLS / OPTIONS / GENERAL / DOCUMENT 7. IN LINK DOCUMENT LOCALIZATION , SELECT OTHER FOLDERS 8. CONFIGURE => SEARCH ORDER IS NOT SAVED . REGRESSION: YES FROM V5R7GA LEVEL . THIS PROBLEM OCCURS ON V5R7SP1 LEVEL. . EXPECTED RESULT: SEARCH ORDER SHOULD BE SAVED. . SYMPTOMS: --------- . IN TOOLS / OPTIONS / GENERAL / DOCUMENT / LINKED DOCUMENT LOCALIZATION: IF ONLY "OTHER FOLDERS" OPTION IS ACTIVATED (WITH YES FLAG) THE ASSEMBLY WON'T BE LOADED IF "OTHER FOLDERS" IS SELECTED WITH ANOTHER "DOCUMENT LOCALIZATION" OPTION (FOR INSTANCE: "FOLDER OF THE LINK"), IT MAY OCCUR THAT THE ASSEMBLY WILL BE PARTIALLY LOADED. . CONSEQUENCES: . 1 - IMPOSSIBLE TO READ A V4 SESSION AND ITS MODELS SAVED UNDER DIFFERENT DIRECTORIES 2 - IMPOSSIBLE TO READ A V5 CATPRODUCT AND ITS PARTS SAVED UNDER DIFFERENT DIRECTORIES(DEFINED UNDER SEARCH ORDER OPTION) 3 - IMPOSSIBLE TO READ A V4 SESSION UNDER NT ENVIRONMENT 4 - IMPOSSIBLE TO READ A CATPRODUCT SAVED UNDER NT ENVIRONMENT UNDER UNIX ENVIRONMENT (DEFINED UNDER SEARCH ORDER OPTION) 5 - IMPOSSIBLE TO USE IMPORT / EXPORT FUNCTIONS IN OTHER FOLDERS CONFIGURATION PANEL
Local fix
Problem summary
INCIDENT DIAGNOSIS: Impossible to save search order option . TECHNICAL EXPLANATION FOR THE CORRECTION: Problem with license localization . ANSWER AND POSSIBLE BY-PASS: This problem is now corrected .
Problem conclusion
THIS PROBLEM WILL BE FIXED ON CATIA VERSION 5 RELEASE 8 GA level. . NOTE THAT THIS PROBLEM WILL ALSO BE FIXED ON V5R7SP01 which includes the dll: . intel_a\code\bin\CATObjectModelerBase.dll dated 01/08 win_a\code\bin\CATObjectModelerBase.dll dated 01/08 aix_a/code/bin/libCATObjectModelerBase.a dated 01/08 solaris_a/code/bin/libCATObjectModelerBase.so dated 01/08 irix_a/code/bin/libCATObjectModelerBase.so dated 01/08 hpux_a/code/bin/libCATObjectModelerBase.sl dated 01/08 . INCIDENT DIAGNOSIS: Impossible to save search order option. .
Temporary fix
Comments
APAR Information
APAR number
HC82645
Reported component name
CATIA V5 NT_INT
Reported component ID
569151000
Reported release
506
Status
CLOSED PER
PE
NoPE
HIPER
NoHIPER
Special Attention
NoSpecatt
Submitted date
2001-07-31
Closed date
2001-08-28
Last modified date
2001-08-28
APAR is sysrouted FROM one or more of the following:
APAR is sysrouted TO one or more of the following:
Modules/Macros
FILE
Fix information
Fixed component name
CATIA V5 NT_INT
Fixed component ID
569151000
Applicable component levels
R506 PSN
UP