HC82645: IMPOSSIBLE TO SAVE SEARCH ORDER OPTION

Subscribe

You can track all active APARs for this component.

 

APAR status

  • Closed as program error.

Error description

  • WORKBENCH: PRODUCT STRUCTURE
    ABSTRACT: IMPOSSIBLE TO SAVE SEARCH ORDER OPTION
    .
    SCENARIO:
    1. OPEN CATIA V5
    2. TOOLS / OPTIONS / GENERAL / DOCUMENT
    3. IN LINK DOCUMENT LOCALIZATION , SELECT OTHER FOLDERS
    4. CONFIGURE
    5. DEFINE A PATH / ADD / OK / OK:
    6. TOOLS / OPTIONS / GENERAL / DOCUMENT
    7. IN LINK DOCUMENT LOCALIZATION , SELECT OTHER FOLDERS
    8. CONFIGURE
    => SEARCH ORDER IS NOT SAVED
    .
    REGRESSION: YES FROM V5R7GA LEVEL
    .
    THIS PROBLEM OCCURS ON V5R7SP1 LEVEL.
    .
    EXPECTED RESULT:
    SEARCH ORDER SHOULD BE SAVED.
    .
    SYMPTOMS:
    ---------
    .
    IN TOOLS / OPTIONS / GENERAL / DOCUMENT / LINKED
    DOCUMENT LOCALIZATION:
    IF ONLY "OTHER FOLDERS" OPTION IS ACTIVATED (WITH YES FLAG)
    THE ASSEMBLY WON'T BE LOADED
    IF "OTHER FOLDERS" IS SELECTED WITH ANOTHER "DOCUMENT
    LOCALIZATION" OPTION (FOR INSTANCE: "FOLDER OF THE LINK"), IT
    MAY OCCUR THAT THE ASSEMBLY WILL BE PARTIALLY LOADED.
    .
    CONSEQUENCES:
    .
    1 - IMPOSSIBLE TO READ A V4 SESSION AND ITS MODELS SAVED UNDER
        DIFFERENT DIRECTORIES
    2 - IMPOSSIBLE TO READ A V5 CATPRODUCT AND ITS PARTS SAVED UNDER
        DIFFERENT DIRECTORIES(DEFINED UNDER SEARCH ORDER OPTION)
    3 - IMPOSSIBLE TO READ A V4 SESSION UNDER NT ENVIRONMENT
    4 - IMPOSSIBLE TO READ A CATPRODUCT SAVED UNDER NT ENVIRONMENT
        UNDER UNIX ENVIRONMENT (DEFINED UNDER SEARCH ORDER OPTION)
    5 - IMPOSSIBLE TO USE IMPORT / EXPORT FUNCTIONS IN OTHER FOLDERS
        CONFIGURATION PANEL
    

Local fix

Problem summary

  •  INCIDENT DIAGNOSIS:
    Impossible to save search order option
    .
     TECHNICAL EXPLANATION FOR THE CORRECTION:
    Problem with license localization
     .
     ANSWER AND POSSIBLE BY-PASS:
    This problem is now corrected
     .
    

Problem conclusion

  • THIS PROBLEM WILL BE FIXED ON
      CATIA VERSION 5 RELEASE 8 GA level.
    .
    NOTE THAT THIS PROBLEM WILL ALSO BE FIXED ON V5R7SP01
     which includes the dll:
    .
    intel_a\code\bin\CATObjectModelerBase.dll dated   01/08
    win_a\code\bin\CATObjectModelerBase.dll dated 01/08
    aix_a/code/bin/libCATObjectModelerBase.a dated  01/08
    solaris_a/code/bin/libCATObjectModelerBase.so dated 01/08
    irix_a/code/bin/libCATObjectModelerBase.so dated 01/08
    hpux_a/code/bin/libCATObjectModelerBase.sl dated  01/08
    .
     INCIDENT DIAGNOSIS:
    Impossible to save search order option. .
    

Temporary fix

Comments

APAR Information

  • APAR number

    HC82645

  • Reported component name

    CATIA V5 NT_INT

  • Reported component ID

    569151000

  • Reported release

    506

  • Status

    CLOSED PER

  • PE

    NoPE

  • HIPER

    NoHIPER

  • Special Attention

    NoSpecatt

  • Submitted date

    2001-07-31

  • Closed date

    2001-08-28

  • Last modified date

    2001-08-28

  • APAR is sysrouted FROM one or more of the following:

  • APAR is sysrouted TO one or more of the following:

Modules/Macros

  •    FILE
    

Fix information

  • Fixed component name

    CATIA V5 NT_INT

  • Fixed component ID

    569151000

Applicable component levels

  • R506 PSN

       UP