  • ABSTRACT: GEN DRAFT - Dimensions not updated when component is
    replaced.
    
    Problem Description:
    PREASSIGNED NUMBER: ALFH-4UFKCB  Needed for Prod Pilot
    Dimensions not updated when component replaced
    
    Scenario:
    1) Open the file
    ALFH-4UFKCB-Dimensions_not_updated_when_component_replaced.CATDr
    2) Select Edit+links and 'Pointed Documents' tab in the
    window
    3) Select 'Open' command: the product is now open
    4) Select the command 'Replace Component' in the Assembly
    Design worbench and select 'Plate1(Plate) in the tree
    5) Select the part 'Plate3': the part is now replaced.
    Notice that Plate3 is thinner and smaller that Plate1.
    6)  Update the assembly and switch to the CATDrawing
    window: Notice that the drawing needs an Update
    7) Update the Drawing
    ==> Look at the dimensions:
    - The dimension 17 did not change: It should be 16 .
    - The 2 dimesions 5 also did not change: They should be
    7.5
    

Local fix

Problem summary

  • Dimensions are not updated when a component is replaced by
    another one in the product.
    

Problem conclusion

  • THIS PROBLEM WILL BE FIXED ON
      CATIA VERSION 5 RELEASE 7 GA level.
    NOTE THAT THIS PROBLEM WILL ALSO BE FIXED ON V5R6SP3.
    
     INCIDENT DIAGNOSIS:
    Dimensions are not updated when a component is replaced by
    another one in the product.
    
     TECHNICAL EXPLANATION FOR THE CORRECTION:
    The dimension links are not modified in such a case.
    
     ANSWER AND POSSIBLE BY-PASS:
    The modification of the dimension links has been delivered for
    the V5R6SP3 version .
    

Temporary fix

Comments

APAR Information

  • APAR number

    HC79557

  • Reported component name

    CATIA V5 NT_INT

  • Reported component ID

    569151000

  • Reported release

    506

  • Status

    CLOSED PER

  • PE

    NoPE

  • HIPER

    NoHIPER

  • Special Attention

    NoSpecatt

  • Submitted date

    2001-04-18

  • Closed date

    2001-05-16

  • Last modified date

    2001-05-16

  • APAR is sysrouted FROM one or more of the following:

  • APAR is sysrouted TO one or more of the following:

Modules/Macros

  •    FILE
    

Fix information

  • Fixed component name

    CATIA V5 NT_INT

  • Fixed component ID

    569151000

Applicable component levels

  • R506 PSN

       UP

[{"Business Unit":{"code":"BU053","label":"Cloud & Data Platform"},"Product":{"code":"SSVJ2K","label":"CATIA V5"},"Component":"","ARM Category":[],"Platform":[{"code":"PF025","label":"Platform Independent"}],"Version":"506","Edition":"","Line of Business":{"code":"LOB10","label":"Data and AI"}}]

Document Information

Modified date:
16 May 2001