IBM Support

HC75218: CATIA VIEWER UPDATE THRU AUTOMATION DOES NOT WORK (VBSCRIPT)

Subscribe

You can track all active APARs for this component.

 

APAR status

  • Closed as program error.

Error description

  • Abstract:
    CATIA Viewer update thru automation does not work
    .
    The command MyViewer.Update() does not work.
    Scenario:
    - Open the CATPart
    - Open the Excel file
    - Enable Macros when opening the file
    - Tile Excel and CATIA on the screen so that both can be seen at
    the same time.
    - Click the button in Excel (This will go to the CATIA part and
    change the position of one of the endpoints)
    - Notice the viewer reframe worked, but the geometry did not
    change
    - Run the cursor over the CATIA window .... Now the viewer
    updates to reflect the change
    --> This should happen automatically with the
    Catia.ActiveWindow.ActiveViewer.Update Command
    .
    Below is an exerpt from programming Interface Documentation:
    .
    - Sub Update ( )
     Updates the viewer's contents. Since the viewer is not
    automatically updated after a viewpoint modification (form
    performance reasons), it must be explicetely redrawn when
    needed.
    Example:
    This example updates the contents of the MyViewer viewer:
         MyViever.Update()
    

Local fix

Problem summary

  • CATIA VIEWER UPDATE THRU AUTOMATION DOES NOT WORK (VBSCRIPT).
    

Problem conclusion

  • THIS PROBLEM WILL BE FIXED ON
      CATIA VERSION 5 RELEASE 7 GA level.
    NOTE THAT THIS PROBLEM IS NOT FIXED ON V5R5SPx and V5R6SPx.
    
     INCIDENT DIAGNOSIS:
    No Viewer update after the execution of VSCript commands.
    
     TECHNICAL EXPLANATION FOR THE CORRECTION:
    after the Part update, the visualisation rebuild was not
    trigerred a synchronous way.
    
     ANSWER AND POSSIBLE BY-PASS:
    Visualisation update is now correct.
    

Temporary fix

Comments

APAR Information

  • APAR number

    HC75218

  • Reported component name

    CATIA V5 NT_INT

  • Reported component ID

    569151000

  • Reported release

    505

  • Status

    CLOSED PER

  • PE

    NoPE

  • HIPER

    NoHIPER

  • Special Attention

    NoSpecatt

  • Submitted date

    2001-01-04

  • Closed date

    2001-03-30

  • Last modified date

    2001-03-30

  • APAR is sysrouted FROM one or more of the following:

  • APAR is sysrouted TO one or more of the following:

Modules/Macros

  •    FILE
    

Fix information

  • Fixed component name

    CATIA V5 NT_INT

  • Fixed component ID

    569151000

Applicable component levels

  • R505 PSN

       UP

  • R506 PSN

       UP

[{"Business Unit":{"code":"BU053","label":"Cloud & Data Platform"},"Product":{"code":"SSVJ2K","label":"CATIA V5"},"Component":"","ARM Category":[],"Platform":[{"code":"PF025","label":"Platform Independent"}],"Version":"505","Edition":"","Line of Business":{"code":"LOB10","label":"Data and AI"}}]

Document Information

Modified date: