APAR status
Closed as program error.
Error description
Scenario : 1- File + open and select the file Assembly.CATProduct 2- File + open and select the file ballon.CATDrawing 3- Double click on the balloon icon. 4- Select the red line and indicate the position of the balloon and press OK. 5- Select the green line and indicate the position of the balloon and press OK. 6- Select the blue line and indicate the position of the balloon and press OK. 7- The result should be like in following picture: 8- Switch to the Assembly.CATProduct window. 9- Select the "Graph tree Reordering" icon. 10- Select the top level of the specification three. 11- In the list select the part with name top and press the up arrow twice 12- Press OK. 13- Select the "Generate Numbering" icon and select the top level of the assembly. 14- Mode should be Integer and existing numbers should be replaced. 15- Press OK. 16- Press MB3 on the instance named "top (top.1)" and select properties option. 17- Notice that the instance number is now "1" before the renumbering it was "3" 18- Switch to the drawing window. 19- Notice that the "update" icon is not activated, which it should because you have reordered the product. 20- Press the "Force update" icon. Result: Nothing happens. This is an error, because if you look in online manual it tells you following: "Note that if you modify the numbering in the product and then regenerate the product, the balloon modification will be applied to the generated views only after you perform a view update".
Local fix
Problem summary
Problem summary : Ballons are not associative after reordering
Problem conclusion
THIS PROBLEM WILL BE FIXED ON CATIA VERSION 5 RELEASE 8 GA level. NOTE THAT THIS PROBLEM WILL ALSO BE FIXED ON V5R7SP2. INCIDENT DIAGNOSIS: A c:force update corrects the problem with the balloons but the update icon is still not available. so the closure type for this part is SUG.
Temporary fix
Comments
APAR Information
APAR number
HC73030
Reported component name
CATIA V5 NT_INT
Reported component ID
569151000
Reported release
504
Status
CLOSED PER
PE
NoPE
HIPER
NoHIPER
Special Attention
NoSpecatt
Submitted date
2000-10-24
Closed date
2001-08-02
Last modified date
2001-09-12
APAR is sysrouted FROM one or more of the following:
APAR is sysrouted TO one or more of the following:
Modules/Macros
FILE
Fix information
Fixed component name
CATIA V5 NT_INT
Fixed component ID
569151000
Applicable component levels
R504 PSN
UP
R505 PSN
UP
R506 PSN
UP
[{"Business Unit":{"code":"BU053","label":"Cloud & Data Platform"},"Product":{"code":"SSVJ2K","label":"CATIA V5"},"Component":"","ARM Category":[],"Platform":[{"code":"PF025","label":"Platform Independent"}],"Version":"504","Edition":"","Line of Business":{"code":"LOB10","label":"Data and AI"}}]
Document Information
Modified date: