IBM Support

HC73030: BALLOONS ARE NOT ASSOCIATIVE AFTER REORDERING.

Subscribe

You can track all active APARs for this component.

 

APAR status

  • Closed as program error.

Error description

  • Scenario :
    1- File + open and select the file Assembly.CATProduct
    2- File + open and select the file ballon.CATDrawing
    3- Double click on the balloon icon.
    4- Select the red line and indicate the position of the balloon
       and press OK.
    5- Select the green line and indicate the position of the
       balloon and press OK.
    6- Select the blue line and indicate the position of the balloon
       and press OK.
    7- The result should be like in following picture:
    8- Switch to the Assembly.CATProduct window.
    9- Select the "Graph tree Reordering" icon.
    10- Select the top level of the specification three.
    11- In the list select the part with name top and press the up
    arrow twice
    12- Press OK.
    13- Select the "Generate Numbering" icon and select the top
    level of the assembly.
    14- Mode should be Integer and existing numbers should be
    replaced.
    15- Press OK.
    16- Press MB3 on the instance named "top (top.1)" and select
       properties option.
    17- Notice that the instance number is now "1" before the
    renumbering it was "3"
    18- Switch to the drawing window.
    19- Notice that the "update" icon is not activated, which it
    should because you have reordered the product.
    20- Press the "Force update" icon.
    Result:
    Nothing happens.
    This is an error, because if you look in online manual it tells
    you following:
    "Note that if you modify the numbering in the product and then
    regenerate the product, the balloon modification will be applied
    to the generated views only after you perform a view update".
    

Local fix

Problem summary

  • Problem summary :
    Ballons are not associative after reordering
    

Problem conclusion

  • THIS PROBLEM WILL BE FIXED ON
      CATIA VERSION 5 RELEASE 8 GA level.
    NOTE THAT THIS PROBLEM WILL ALSO BE FIXED ON V5R7SP2.
    
     INCIDENT DIAGNOSIS:
    A c:force update corrects the problem with the balloons
    but the update icon is still not available.
    so the closure type for this part is SUG.
    

Temporary fix

Comments

APAR Information

  • APAR number

    HC73030

  • Reported component name

    CATIA V5 NT_INT

  • Reported component ID

    569151000

  • Reported release

    504

  • Status

    CLOSED PER

  • PE

    NoPE

  • HIPER

    NoHIPER

  • Special Attention

    NoSpecatt

  • Submitted date

    2000-10-24

  • Closed date

    2001-08-02

  • Last modified date

    2001-09-12

  • APAR is sysrouted FROM one or more of the following:

  • APAR is sysrouted TO one or more of the following:

Modules/Macros

  •    FILE
    

Fix information

  • Fixed component name

    CATIA V5 NT_INT

  • Fixed component ID

    569151000

Applicable component levels

  • R504 PSN

       UP

  • R505 PSN

       UP

  • R506 PSN