APAR status
Closed as program error.
Error description
PROBLEM DESCRIPTION: It is not possible to assemble 2 bodies. Error message: "Assemble.6: Topological operators: internal error". This problem is model dependant. SCENARIO: 1. Open AROSA1.CATPart 2. Try to Add or Assemble the Body.5 and PartBody : ==> Error message: "Assemble.6: Topological operators: internal error"
Local fix
Problem summary
INCIDENT DIAGNOSIS: It was impossible to add or assemble two specific bodies. TECHNICAL EXPLANATION FOR THE CORRECTION: The hole of the edgecurve was not correctly updated, and the report to the size of the hole was badly managed. Those problems have been corrected. And the add or assemble between the two bodies are successfull now.
Problem conclusion
THIS PROBLEM WILL BE FIXED ON CATIA VERSION 5 RELEASE 4 GA level . NOTE THAT THIS PROBLEM WILL ALSO BE FIXED ON V5R3SP09.
Temporary fix
Comments
APAR Information
APAR number
HC65134
Reported component name
CATIA V5 NT_INT
Reported component ID
569151000
Reported release
503
Status
CLOSED PER
PE
NoPE
HIPER
NoHIPER
Special Attention
NoSpecatt
Submitted date
2000-05-02
Closed date
2000-05-29
Last modified date
2000-07-06
APAR is sysrouted FROM one or more of the following:
APAR is sysrouted TO one or more of the following:
Modules/Macros
FILE
Fix information
Fixed component name
CATIA V5 NT_INT
Fixed component ID
569151000
Applicable component levels
R003 PSN SP00309
UP00/07/06 I 1000
R103 PSN SP10309
UP00/07/06 I 1000
R203 PSN SP20309
UP00/07/06 I 1000
R303 PSN SP30309
UP00/07/06 I 1000
R503 PSN SP50309
UP00/07/06 I 1000
[{"Business Unit":{"code":"BU053","label":"Cloud & Data Platform"},"Product":{"code":"SSVJ2K","label":"CATIA V5"},"Component":"","ARM Category":[],"Platform":[{"code":"PF025","label":"Platform Independent"}],"Version":"503","Edition":"","Line of Business":{"code":"LOB10","label":"Data and AI"}}]
Document Information
Modified date:
06 July 2000