Error description
SCENARIO : 1. SKIN/FEATURE/SKIN/SWEEP 2. Select the center curve 3. Select the reference surface (boundaries in no pick) 4. Select the contour curve 5. Yes : Create --> the surface boundaries are in pick --> click on BR icon --> the boundaries get back in no pick
Local fix
Problem summary
INCIDENT DIAGNOSIS: When creating a SWEEP with an explicit reference element ( * SUR *FAC or *SKI), the reference boundaries change from NOPICK to PICK vizualisation.
Problem conclusion
THIS PROBLEM WILL BE FIXED ON CATIA VERSION 4 RELEASE 2.1 REFRESH 1 GA level (FREL421R1) The reference element vizualisation was not refreshed. This problem has been corrected, clicking on BR is not required after the sweep creation, the reference surface boundaries are still in NO PICK. . By-pass: Refresh the vizualisation by selecting the BR permanent button.
Temporary fix
Comments
APAR Information
APAR number
HC43057
Reported component name
CATIA FOR H.P.
Reported component ID
562620000
Reported release
G20
Status
CLOSED PER
PE
NoPE
HIPER
NoHIPER
Special Attention
NoSpecatt
Submitted date
1999-02-15
Closed date
1999-03-04
Last modified date
1999-06-02
APAR is sysrouted FROM one or more of the following:
APAR is sysrouted TO one or more of the following:
UB61254
Modules/Macros
FILE
Fix information
Fixed component name
CATIA FOR H.P.
Fixed component ID
562620000
Applicable component levels
RG20 PSY UB61254
UP99/03/16 I 1000
RH20 PSY
UP
R421 PSY UB92111
UP99/06/02 I 1000