Error description
ABSTRACT: Fillet cannot be created in SOLIDE with a chamfer. SCENARIO: 1) File/Read the model. 2) Function SOLIDE/OPERATN/FILLET - Rolling Edge 3) SEL the edge under the blue line 4) YES: END 5) SEL the edge under the red line 6) Enter radius value = 2.0 7) YES: COMPUTE => MSG ERROR: IMPOSSIBLE FILLET RELIMITATION
Local fix
Problem summary
INCIDENT DIAGNOSIS: It is not possible to create a fillet with rolling edge on a specific geometry (a corner with four edges, 2 arcs and 2 segments). Error MSG IMPOSSIBLE FILLET RELIMITATION.
Problem conclusion
THIS PROBLEM IS PERMANENT RESTRICTION IN CATIA The algorithm tries to extrapole in tangency the top surface of the chamfer. As the two top surfaces are not plane, the algorithm fails.