APAR status
Closed as Permanent restriction.
Error description
SCENARIO: -------- 1- FILE+READ to read the supplied model 2- Run /CLN 168 events of Category 2 and 92 events of Category 3 detected Delete all these events (all views and dittos) 3- Select VU switch 4- Enter ===> Error 709 Invalid logical link assigned to basic subroutine The problem may lie with a non-extistent background plane detected by cln or with the VU switch. .
Local fix
Problem summary
INCIDENT DIAGNOSIS: SELECTING VU SWITCH CAUSES AN 709 ERROR EVEN AFTER CLEANING THE THE MODEL
Problem conclusion
THIS PROBLEM IS PERMANENT RESTRICTION IN CATIA TECHNICAL EXPLANATION FOR THE RESTRICTION: In fact, the model conatins several bad elements which cannot be reparable by the cleaner, even if it has cleaned other elements included in this model. In the present CATIA V4 software, it is not possible to clean all the possible bad elements from the model. It is partially a permanent restriction. .
Temporary fix
Comments
APAR Information
APAR number
HC42250
Reported component name
CATIA FOR SUN
Reported component ID
562640000
Reported release
G20
Status
CLOSED PRS
PE
NoPE
HIPER
NoHIPER
Special Attention
NoSpecatt
Submitted date
1999-01-28
Closed date
1999-08-23
Last modified date
1999-08-23
APAR is sysrouted FROM one or more of the following:
APAR is sysrouted TO one or more of the following:
Fix information
Applicable component levels
[{"Business Unit":{"code":"BU053","label":"Cloud & Data Platform"},"Product":{"code":"SSLJ45","label":"CATIA-CADAM"},"Component":"","ARM Category":[],"Platform":[{"code":"PF025","label":"Platform Independent"}],"Version":"G20","Edition":"","Line of Business":{"code":"LOB10","label":"Data and AI"}}]
Document Information
Modified date:
23 August 1999