  • Closed as Permanent restriction.

Error description

  • When dimensionning a radius with DIMENS2/CREATE/RADIUS/CIR CNT
    on the section view of a revolution cylinder, the radius is
    displayed at the opposite side of the view.
    

Local fix

Problem summary

  •  INCIDENT DIAGNOSIS:
    DIMENS2/CREATE/RADIUS/CIR CNT creates the radius at wrong
    location
    

Problem conclusion

  •  TECHNICAL EXPLANATION FOR THE RESTRICTION:
    The location of the radius depends of the curves resulting from
    the intersection between the cutting plane and the fillet
    surface.
    In this case, there is only one curve solution (instead of two
    expected by the user), and it is not the 'good' one (the
    nearest from the selected point).
    Why there is only one solution ?
    Because, the plane does not cut totally the surface.
    The boundary of the surface is at a distance greater than the
    tolerance used in the intersection plane/surface algorithm.
    (you can see it using analysis/relative function).
    The distance is more than 5*tol2.
    And the tolerance used in the algorithm is tol2 (i.e intersec-
    tion projection tolerance in the standard/model function).
    We cannot modify this tolerance without any regression.
    
     BY-PASS:
    Make a little rotation of the solid in order that the plane
    does not cut the surface on the boundary.
    

Temporary fix

Comments

APAR Information

  • APAR number

    HC40554

  • Reported component name

    CATIA FOR AIX

  • Reported component ID

    562610000

  • Reported release

    G20

  • Status

    CLOSED PRS

  • PE

    NoPE

  • HIPER

    NoHIPER

  • Special Attention

    NoSpecatt

  • Submitted date

    1998-12-10

  • Closed date

    1999-10-14

  • Last modified date

    1999-10-14

  • APAR is sysrouted FROM one or more of the following:

    HC40553

  • APAR is sysrouted TO one or more of the following:

Fix information

Applicable component levels

[{"Business Unit":{"code":"BU053","label":"Cloud & Data Platform"},"Product":{"code":"SSLJ45","label":"CATIA-CADAM"},"Component":"","ARM Category":[],"Platform":[{"code":"PF025","label":"Platform Independent"}],"Version":"G20","Edition":"","Line of Business":{"code":"LOB10","label":"Data and AI"}}]

Document Information

Modified date:
14 October 1999