IBM Support

DY46964: MPC ACTIVATION FAILS WHEN ONE WRITE OR READ SUBCHANNEL IS NOT OPERATIONAL.

A fix is available

 

APAR status

  • Closed as program error.

Error description

  • MPC activation fails when one write or read subchannel is not
    operational. In this case condition code 3 was received in
    response to SSCH because the device was not physically there.

Local fix

Problem summary

  • ****************************************************************
    * USERS AFFECTED: All using subarea MPC connections. *
    ****************************************************************
    * PROBLEM DESCRIPTION: MPC activation fails if any of *
    * the WRITE or READ subchannels *
    * are OFFLINE at activation time. *
    ****************************************************************
    * RECOMMENDATION: *
    ****************************************************************
    The problem is summarized as follows:
    1) An MPC connection, configured with two or more READ/WRITE
    subchannels, fails activation if any of the subchannels
    are OFFLINE during activation.
    2) During ACTLINK processing, all of the defined subchannels
    addresses for the MPC link are allocated from VSE.
    The channel allocation is successful even though they
    may be OFFLINE. VSE does not perform channel path
    validation.
    3) After the channels are allocated, channel programs are
    initiated. The OFFLINE subchannels receive a SIO CC3
    indicating they are unavailable.
    4) The ACTLINK request for each OFFLINE subchannel is
    failed. This results in a SENSE 081C0000 being sent to
    the console for the ACTLINK failure. The entire MPC
    LINE is brought down.
    5) This APAR is being taken to tolerate an OFFLINE MPC
    channel at activation. The MPC connection will continue
    with activation as long as one READ and one WRITE
    subchannel have successful ACTLINK processing.

Problem conclusion

  • ISTTSCM8 - Subroutine ACTLINK has been modified to tolerate
    negative responses. Instead of going into
    a takedown FSM upon receipt of a negative
    response to an ACTLINK, the SCL_STATE for the
    subchannel is set to SCL_INOP state. When all
    the outstanding ACTLINK responses are received,
    a scan is performed to verify there is at least
    one available READ and one available WRITE
    subchannel. Processing continues if an available
    WRITE/READ are found. Otherwise, the MPC
    connection is taken down with sense 081C0000 to
    the ACTLINK (as before).
    ISTTSC8E - Included for maintenance purposes.

Temporary fix

Comments

APAR Information

  • APAR number

    DY46964

  • Reported component name

    VTAM V4 VSE/ESA

  • Reported component ID

    568606501

  • Reported release

    FE6

  • Status

    CLOSED PER

  • PE

    NoPE

  • HIPER

    NoHIPER

  • Special Attention

    NoSpecatt

  • Submitted date

    2008-09-03

  • Closed date

    2008-10-01

  • Last modified date

    2009-05-14

  • APAR is sysrouted FROM one or more of the following:

  • APAR is sysrouted TO one or more of the following:

    UD53407

Modules/Macros
ISTTSCM8ISTTSC8E    

Fix information

  • Fixed component name

    VTAM V4 VSE/ESA

  • Fixed component ID

    568606501

Applicable component levels

  • RFE6 PSY UD53407

       UP08/11/05 P E421

Fix is available

  • Select the PTF appropriate for your component level. You will be required to sign in. Distribution on physical media is not available in all countries.

[{"Business Unit":{"code":"BU058","label":"IBM Infrastructure w\/TPS"},"Product":{"code":"SS5KWR","label":"ACF\/VTAM"},"Component":"","ARM Category":[],"Platform":[{"code":"PF025","label":"Platform Independent"}],"Version":"FE6","Edition":"","Line of Business":{"code":"LOB35","label":"Mainframe SW"}}]