HD32955: STEP / SURFACE IS LOST AFTER STEP CONVERSION.

Subscribe

You can track all active APARs for this component.

 

APAR status

  • Closed as Permanent restriction.

Error description

  • STEP / SURFACE IS LOST AFTER STEP
    CONVERSION.
    .
    

Local fix

Problem summary

  • STEP / SURFACE IS LOST AFTER STEP CONVERSION.
    STEP / SURFACE IS LOST AFTER STEP
    CONVERSION.
    .
    

Problem conclusion

  • THIS PROBLEM IS PERMANENT
    RESTRICTION IN CATIA.
    .
    Incident Diagnosis:
    Step face import fails in optimized mode
    producing 463x4=1852 CATSurface (!) but is
    correctly imported with non-optimised mode
    producing 561x4=2244 CATSurface (!!!)
    .
    Restriction Explanation:
    The C2 cutting provides a huge set of
    CATSurface in both modes
    (optim/nonoptim).
    But, in optim mode, the CATPCurve
    representation of the boundary of the face
    present lots of holes between CATPCurves.
    See attached jpg file
    Detail_MF40781_KO_optim.jpg showing one,
    AMONG DOZENS, of such incorrect gaps
    between edges and/or between CATPCurve
    inside an edge.
    (N.B. : text are not meaninfull in this
    purpose. Only image is meaningfull).
    On such poor quality models, we use some
    heuristics in order to restore a probable
    connexity between CATPCurves.
    Given the huge number of holes, these
    heuristics fail when trying to discard
    CATPCurve and/or retrieve which of them
    are good ones or not.
    .
    The quality of CATPCurve is much more
    better in NON-optimized mode than in
    optimized, which is quite strange.
    .
    We tried to modify internal CATPCurve
    reconcialiation heuristics but without
    success, even many (and costly) trials.
    .
    Low quality of CATPCurve representation
    (STEP file given or laydowned) multiplied by
    huge CATSurface number, also revealing a
    low surfacic quality, seem to be responsible
    of the KO.
    .
    By-Pass:
    Use non-optimized mode instead of
    optimized mode.
    .
    

Temporary fix

Comments

APAR Information

  • APAR number

    HD32955

  • Reported component name

    CATIA V5 NT>XP

  • Reported component ID

    569151000

  • Reported release

    514

  • Status

    CLOSED PRS

  • PE

    NoPE

  • HIPER

    NoHIPER

  • Special Attention

    NoSpecatt

  • Submitted date

    2005-01-04

  • Closed date

    2005-05-18

  • Last modified date

    2005-05-18

  • APAR is sysrouted FROM one or more of the following:

  • APAR is sysrouted TO one or more of the following:

Fix information

Applicable component levels

[{"Business Unit":{"code":"BU053","label":"Cloud & Data Platform"},"Product":{"code":"SSVJ2K","label":"CATIA V5"},"Component":"","ARM Category":[],"Platform":[{"code":"PF025","label":"Platform Independent"}],"Version":"514","Edition":"","Line of Business":{"code":"LOB10","label":"Data and AI"}}]

Document Information

Modified date:
18 May 2005