APAR status
Closed as program error.
Error description
INT V4-V5 BROWSER : File Open of a CATIA V4 model in CATIA V5 leads to a CPU loop . .
Local fix
Problem summary
INT V4-V5 BROWSER : File Open of a CATIA V4 model in CATIA V5 l eads to a CPU loop . INT V4-V5 BROWSER : File Open of a CATIA V4 model in CATIA V5 leads to a CPU loop . .
Problem conclusion
THIS PROBLEM WILL BE FIXED ON CATIA VERSION 5 RELEASE 15 GA level. NOTE THAT THIS PROBLEM WILL ALSO BE FIXED ON V5R14SP05 . There was a CPU loop in the meshing of a body. The correction consists in a protection against the deletion of meshing bars : CPU loop is no more reproduced. . More an edge and a face created by Shell.1 feature cannot be migrated due to too important gaps in the face. There is a by-pass : Edit Shell.1, Decrease value from 6. to 5., Increase value from 5. to 6., Click OK. The Update is successfull and then File Save As model is correctly performed. .
Temporary fix
Comments
APAR Information
APAR number
HD31127
Reported component name
CATIA V5 AIX
Reported component ID
569101000
Reported release
512
Status
CLOSED PER
PE
NoPE
HIPER
NoHIPER
Special Attention
NoSpecatt
Submitted date
2004-11-24
Closed date
2005-02-03
Last modified date
2009-06-24
APAR is sysrouted FROM one or more of the following:
APAR is sysrouted TO one or more of the following:
Fix information
Fixed component name
CATIA V5 AIX
Fixed component ID
569101000
Applicable component levels
R514 PSN SP51405
UP05/03/31 N 1000
[{"Business Unit":{"code":"BU053","label":"Cloud & Data Platform"},"Product":{"code":"SSVJ2K","label":"CATIA V5"},"Component":"","ARM Category":[],"Platform":[{"code":"PF025","label":"Platform Independent"}],"Version":"512","Edition":"","Line of Business":{"code":"LOB10","label":"Data and AI"}}]
Document Information
Modified date:
24 June 2009