Error description

  • Catia V5 crashes with the 'command interrupted'
    error if the  CATStartupPath variable exceeds 210
    characters.
    .
    Scenario:
    Abstract -
    Catia V5 crashes with the command interrupted
    error if the CATStartupScript variable in
    the 'CATIA_P3.V5R11.B11.txt' file is set to more
    than 210 characters.
    This happens only if the "Load Extended Language
    Libraries" option in ON in the Tools => Options
    panel.
    .
    Scenario -
    1 - Open the CatiaV5 environment file
    CATIA_P3.V5R11.B11.txt
    2 - Set the CATStartupPath variable to a path that
    is more than 210 characters.
    3 - Launch Catia V5
    4 - Click on Tools => Options => Parameters &
    Measures
    5 - Check the 'Load Extended Language Libraries'
    option.
    6 - Exit Catia V5 and launch again.
    7 - Download the files TestItem.CATScript and
    Part11.CATPart files attached to this PMR into a
    local directory.
    8 - In Catia V5 open the Part11.CATPart attached
    to this PMR.
    9 - Click on Tools=>Macro=>Macros - The macros
    panel pops up.
    10- Locate the TestItem.CATScript file and Click
    Run.
    Catia crashes with the command interrupted error.
    .
    Notes -
    1 - If the CATStartupPath variable path is less than
    210 characters everything works fine.
    2 - Tests were done on Catia V5R11 SP02 and
    Catia V5R13 SP03 and the results are exactly the
    same.
    .
    

Local fix

Problem summary

  • Catia V5 crashes with the 'command interrupted' error if the  C
    ATStartupPath variable exceeds 210 characters
    Catia V5 crashes with the 'command interrupted'
    error if the  CATStartupPath variable exceeds 210
    characters.
    .
    Scenario:
    Abstract -
    Catia V5 crashes with the command interrupted
    error if the CATStartupScript variable in
    the 'CATIA_P3.V5R11.B11.txt' file is set to more
    than 210 characters.
    This happens only if the "Load Extended Language
    Libraries" option in ON in the Tools => Options
    panel.
    .
    Scenario -
    1 - Open the CatiaV5 environment file
    CATIA_P3.V5R11.B11.txt
    2 - Set the CATStartupPath variable to a path that
    is more than 210 characters.
    3 - Launch Catia V5
    4 - Click on Tools => Options => Parameters &
    Measures
    5 - Check the 'Load Extended Language Libraries'
    option.
    6 - Exit Catia V5 and launch again.
    7 - Download the files TestItem.CATScript and
    Part11.CATPart files attached to this PMR into a
    local directory.
    8 - In Catia V5 open the Part11.CATPart attached
    to this PMR.
    9 - Click on Tools=>Macro=>Macros - The macros
    panel pops up.
    10- Locate the TestItem.CATScript file and Click
    Run.
    Catia crashes with the command interrupted error.
    .
    Notes -
    1 - If the CATStartupPath variable path is less than
    210 characters everything works fine.
    2 - Tests were done on Catia V5R11 SP02 and
    Catia V5R13 SP03 and the results are exactly the
    same.
    .
    

Problem conclusion

  • THIS PROBLEM WILL BE FIXED ON CATIA VERSION
    5 RELEASE 14 GA level.
    NOTE THAT THIS PROBLEM WILL ALSO BE FIXED
    ON V5R13SP5.
    .
    Incident Diagnosis
    the path length use in the setting file is bigger than
    the maximum size allowed. Therefore it leads to a
    crash on sun.
    .
    Correction Explanation
    We change the array of char to a
    CATUnicodeString that has no length restriction
    .
    Answer and By-Pass
    None.
    .
    

Temporary fix

Comments

APAR Information

  • APAR number

    HD23732

  • Reported component name

    CATIA V 5 SUN

  • Reported component ID

    569104000

  • Reported release

    511

  • Status

    CLOSED PER

  • PE

    NoPE

  • HIPER

    NoHIPER

  • Special Attention

    NoSpecatt

  • Submitted date

    2004-06-14

  • Closed date

    2004-07-01

  • Last modified date

    2009-06-24

  • APAR is sysrouted FROM one or more of the following:

  • APAR is sysrouted TO one or more of the following:

Fix information

  • Fixed component name

    CATIA V 5 SUN

  • Fixed component ID

    569104000

Applicable component levels

  • R513 PSN SP51305

       UP04/07/16 N 1000

  • R514 PSN

       UP