HD20229: PMG / MACHINING AXIS SYSTEM NOT RECOGNIZED WHEN INSERT MO FROM CATALOG

Subscribe

You can track all active APARs for this component.

 

APAR status

  • Closed as program error.

Error description

  • PMG / MACHINING AXIS SYSTEM NOT
    RECOGNIZED WHEN INSERT MO FROM CATALOG
    .
    

Local fix

Problem summary

  • PMG / MACHINING AXIS SYSTEM NOT RECOGNIZED WHEN INSERT MO FROM
    CATALOG
    PMG / MACHINING AXIS SYSTEM NOT
    RECOGNIZED WHEN INSERT MO FROM CATALOG
    .
    

Problem conclusion

  • THIS PROBLEM WILL BE FIXED ON CATIA VERSION
    5 RELEASE 14 GA level.
    .
    ADDITIONAL INFORMATION
    .
    Incident Diagnosis
    When a MP is instantiated, the absolute positions of
    the Tool Axis of its operations are kept => after
    instantiation, and the relative coordinates of the
    ToolAxis may have been changed.
    .
    Correction Explanation
    When the MP is instantiated in a Process using a
    specific axis system, there are two possibilities:
    .
    1- Default behavior:
    The absolute position of the TL axis is kept
    => Its shown coordinates are changed
    .
    2- New possible behavior:
    The shown coordinates of the TL axis are kept
    => Its absolute position is changed but its
    expression is kept.
    .
    The choice between behavior 1 and 2 is a
    Machining Option (CAT Settings):
    Tools > Options > Machining > Operation >
    "MP Instantiation: keep default position of the tool
    axis".
    By default this option is checked.
    .
    After the instantiation, the Tool Axis has the same
    behavior as others tool axis, in particular: if the
    instantiated activity is pasted in a different context,
    then the Tool Axis keeps its absolute position.
    .
    Answer and By-Pass
    No by-pass
    .
    

Temporary fix

Comments

APAR Information

  • APAR number

    HD20229

  • Reported component name

    CATIA V5/NT/200

  • Reported component ID

    569151000

  • Reported release

    512

  • Status

    CLOSED PER

  • PE

    NoPE

  • HIPER

    NoHIPER

  • Special Attention

    NoSpecatt

  • Submitted date

    2004-04-01

  • Closed date

    2004-05-06

  • Last modified date

    2004-05-06

  • APAR is sysrouted FROM one or more of the following:

  • APAR is sysrouted TO one or more of the following:

Fix information

  • Fixed component name

    CATIA V5/NT/200

  • Fixed component ID

    569151000

Applicable component levels

  • R512 PSN

       UP

  • R513 PSN

       UP

[{"Business Unit":{"code":"BU053","label":"Cloud & Data Platform"},"Product":{"code":"SSVJ2K","label":"CATIA V5"},"Component":"","ARM Category":[],"Platform":[{"code":"PF025","label":"Platform Independent"}],"Version":"512","Edition":"","Line of Business":{"code":"LOB10","label":"Data and AI"}}]

Document Information

Modified date:
06 May 2004