APAR status
Closed as program error.
Error description
PMG / MACHINING AXIS SYSTEM NOT RECOGNIZED WHEN INSERT MO FROM CATALOG .
Local fix
Problem summary
PMG / MACHINING AXIS SYSTEM NOT RECOGNIZED WHEN INSERT MO FROM CATALOG PMG / MACHINING AXIS SYSTEM NOT RECOGNIZED WHEN INSERT MO FROM CATALOG .
Problem conclusion
THIS PROBLEM WILL BE FIXED ON CATIA VERSION 5 RELEASE 14 GA level. . ADDITIONAL INFORMATION . Incident Diagnosis When a MP is instantiated, the absolute positions of the Tool Axis of its operations are kept => after instantiation, and the relative coordinates of the ToolAxis may have been changed. . Correction Explanation When the MP is instantiated in a Process using a specific axis system, there are two possibilities: . 1- Default behavior: The absolute position of the TL axis is kept => Its shown coordinates are changed . 2- New possible behavior: The shown coordinates of the TL axis are kept => Its absolute position is changed but its expression is kept. . The choice between behavior 1 and 2 is a Machining Option (CAT Settings): Tools > Options > Machining > Operation > "MP Instantiation: keep default position of the tool axis". By default this option is checked. . After the instantiation, the Tool Axis has the same behavior as others tool axis, in particular: if the instantiated activity is pasted in a different context, then the Tool Axis keeps its absolute position. . Answer and By-Pass No by-pass .
Temporary fix
Comments
APAR Information
APAR number
HD20229
Reported component name
CATIA V5/NT/200
Reported component ID
569151000
Reported release
512
Status
CLOSED PER
PE
NoPE
HIPER
NoHIPER
Special Attention
NoSpecatt
Submitted date
2004-04-01
Closed date
2004-05-06
Last modified date
2004-05-06
APAR is sysrouted FROM one or more of the following:
APAR is sysrouted TO one or more of the following:
Fix information
Fixed component name
CATIA V5/NT/200
Fixed component ID
569151000
Applicable component levels
R512 PSN
UP
R513 PSN
UP