Error description
SMARTEAM CATIA V5 INTEGRATION: Assembly constraints were broken after revision replaced for two Parts under the Product. ... Scenario: [For Client A: Operation 1] 1. Launch CATIA. 2. Create CATPart named TESTPART1. 3. Create CATPart named TESTPART2. 4. Save TESTPART1 and TESTPART2 thru the Save Management. 5. CATIA Menu > SmarTeam > Connect by Joe. 6. CATIA Menu > SmarTeam > Save for TESTPART1. 7. CATIA Menu > SmarTeam > Save for TESTPART2. 8. CATIA Menu > SmarTeam > Lifecycle > Check In for TESTPART1. (Rev.0) 9. CATIA Menu > SmarTeam > Lifecycle > Check In for TESTPART2. (Rev.0) . [For Client B: Operation 1] 1. Launch CATIA. 2. Create CATProduct named CONSTPROD1. 3. Login SMARTEAM Editor by Jim. 4. Find TESTPART1 from Editor. 5. For TESTPART1, SMARTEAM Context Menu > File Operation > Open. (Rev.0) 6. Find TESTPART2 from Editor. 7. For TESTPART2, SMARTEAM Context Menu > File Operation > Open. (Rev.0) 8. Drag and drop TESTPART1 into CONSTPROD1. 9. Drag and drop TESTPART2 into CONSTPROD1. 10. Add two assembly constraints between the Parts. 11. Click the Update icon. 12. Save CONSTPROD1 thru the Save Management. 13. CATIA Menu > SmarTeam > Connect. 14. CATIA Menu > SmarTeam > Save for CONSTPROD1. 15. CATIA Menu > SmarTeam > Lifecycle > Check In for CONSTPROD1. . [For Client A: Operation 2] 1. CATIA Menu > SmarTeam > Change to SMARTEAM. 2. Find TESTPART1 from Editor. 3. For TESTPART1, SMARTEAM Context Menu > File Operation > Open for > Edit. 4. Find TESTPART2 from Editor. 5. For TESTPART2, SMARTEAM Context Menu > File Operation > Open for > Edit. 6. Change the geometries of TESTPART1 and TESTPART2 to impact on the assembly constraints. 7. Save TESTPART1 and TESTPART2 through the Save Management. 8. CATIA Menu > SmarTeam > Lifecycle > Check In for TESTPART1. (Rev.1) 9. CATIA Menu > SmarTeam > Lifecycle > Check In for TESTPART2. (Rev.1) . [For Client B: Operation 2] 1. Find CONSTPROD1 from Editor. 2. For CONSTPROD1, SMARTEAM Context Menu > File Operation > Open. 3. Double click the TESTPART1 in the CATIA tree. 4. CATIA Menu > SmarTeam > Assembly Management > Replace with Selected Revision > Rev. 1 > OK. 5. Double click the TESTPART2 in the CATIA tree. 6. CATIA Menu > SmarTeam > Assembly Management > Replace with Selected Revision > Rev. 1 > OK. 7. Click the Update icon. 8. "Changing to the Design Mode" message is displayed > OK . [Problems: ] 1. The result of Updating, the constraint related Parts are in the Design Mode. 2. At this time, "?" marks on the assembly constraints in the CATIA tree are still active. However, the Constraint Status is "Connected". 3. The result of the operation, the Save Management Status have two ghost Parts with strange names. .
Local fix
Problem summary
Assembly constraints were broken after revision replaced for two Parts under the Product SMARTEAM CATIA V5 INTEGRATION: Assembly constraints were broken after revision replaced for two Parts under the Product. ... Scenario: For Client A: Operation 1 1. Launch CATIA. 2. Create CATPart named TESTPART1. 3. Create CATPart named TESTPART2. 4. Save TESTPART1 and TESTPART2 thru the Save Management. 5. CATIA Menu > SmarTeam > Connect by Joe. 6. CATIA Menu > SmarTeam > Save for TESTPART1. 7. CATIA Menu > SmarTeam > Save for TESTPART2. 8. CATIA Menu > SmarTeam > Lifecycle > Check In for TESTPART1. (Rev.0) 9. CATIA Menu > SmarTeam > Lifecycle > Check In for TESTPART2. (Rev.0) . For Client B: Operation 1 1. Launch CATIA. 2. Create CATProduct named CONSTPROD1. 3. Login SMARTEAM Editor by Jim. 4. Find TESTPART1 from Editor. 5. For TESTPART1, SMARTEAM Context Menu > File Operation > Open. (Rev.0) 6. Find TESTPART2 from Editor. 7. For TESTPART2, SMARTEAM Context Menu > File Operation > Open. (Rev.0) 8. Drag and drop TESTPART1 into CONSTPROD1. 9. Drag and drop TESTPART2 into CONSTPROD1. 10. Add two assembly constraints between the Parts. 11. Click the Update icon. 12. Save CONSTPROD1 thru the Save Management. 13. CATIA Menu > SmarTeam > Connect. 14. CATIA Menu > SmarTeam > Save for CONSTPROD1. 15. CATIA Menu > SmarTeam > Lifecycle > Check In for CONSTPROD1. . For Client A: Operation 2 1. CATIA Menu > SmarTeam > Change to SMARTEAM. 2. Find TESTPART1 from Editor. 3. For TESTPART1, SMARTEAM Context Menu > File Operation > Open for > Edit. 4. Find TESTPART2 from Editor. 5. For TESTPART2, SMARTEAM Context Menu > File Operation > Open for > Edit. 6. Change the geometries of TESTPART1 and TESTPART2 to impact on the assembly constraints. 7. Save TESTPART1 and TESTPART2 through the Save Management. 8. CATIA Menu > SmarTeam > Lifecycle > Check In for TESTPART1. (Rev.1) 9. CATIA Menu > SmarTeam > Lifecycle > Check In for TESTPART2. (Rev.1) . For Client B: Operation 2 1. Find CONSTPROD1 from Editor. 2. For CONSTPROD1, SMARTEAM Context Menu > File Operation > Open. 3. Double click the TESTPART1 in the CATIA tree. 4. CATIA Menu > SmarTeam > Assembly Management > Replace with Selected Revision > Rev. 1 > OK. 5. Double click the TESTPART2 in the CATIA tree. 6. CATIA Menu > SmarTeam > Assembly Management > Replace with Selected Revision > Rev. 1 > OK. 7. Click the Update icon. 8. "Changing to the Design Mode" message is displayed > OK . Problems: 1. The result of Updating, the constraint related Parts are in the Design Mode. 2. At this time, "?" marks on the assembly constraints in the CATIA tree are still active. However, the Constraint Status is "Connected". 3. The result of the operation, the Save Management Status have two ghost Parts with strange names. .
Problem conclusion
Temporary fix
Comments
THE PROBLEM WAS SUBMITTED ON : CATIA VERSION 5 RELEASE 12. THIS PROBLEM IS NOT REPRODUCIBLE ON : CATIA VERSION 5 RELEASE 14 GA level AND ON V5R13SP04 AND V5R12SP07. Incident Diagnosis Code of "replace selected revision" used to work based on produst structure replace component, focused on instances. We now replace all links in session by the one to the new document. Answer and By-Pass: Disconnected constraints after replace are not corrected. The solution to have the entire problem solved is to work with publications. .
APAR Information
APAR number
HD19657
Reported component name
CATIA V5/NT/200
Reported component ID
569151000
Reported release
512
Status
CLOSED UR1
PE
NoPE
HIPER
NoHIPER
Special Attention
NoSpecatt
Submitted date
2004-03-19
Closed date
2004-05-06
Last modified date
2004-05-06
APAR is sysrouted FROM one or more of the following:
APAR is sysrouted TO one or more of the following:
Fix information
Fixed component name
CATIA V5/NT/200
Fixed component ID
569151000
Applicable component levels
R512 PSN
UP
R513 PSN
UP
[{"Business Unit":{"code":"BU053","label":"Cloud & Data Platform"},"Product":{"code":"SSVJ2K","label":"CATIA V5"},"Component":"","ARM Category":[],"Platform":[{"code":"PF025","label":"Platform Independent"}],"Version":"512","Edition":"","Line of Business":{"code":"LOB10","label":"Data and AI"}}]
Document Information
Modified date:
06 May 2004