HD17363: SHAPE DESIGN : THE REFERENCE GEOMETRY BECOMES UNPICKABLE FROM G RAPHICS AREA

Subscribe

You can track all active APARs for this component.

 

APAR status

  • Closed as program error.

Error description

  • Summary of problem:
    'Reference Location.1' can be selected from
    specification tree, but is unpickable in graphical
    area. this is problem.
    .
    < Reproduction >
    1. Start CATIA V5
    2. Open the provided Part1.CATPart
    Workbench : 'GSD'.
    3. Sel 'Reference Location.1' in the unfold 'Mating
    Flange.1' in specification tree.
    >> confirm that 'Reference Location.1' is pickable.
    4. Click anywhere in graphics area.
    5. Sel the geometry of 'Reference Location.1' in
    graphics area.
    >> 'Reference Location.1' is unpickable in graphics
    area.
    >>> this is the problem.
    .
    < Desired Result >
    'Reference Location.1' is expected to be pickable in
    both specification tree and graphics area.
    .
    < Remarks >
    A by-pass is illustrated as follows:
    1. Choose the 'Properties' command from the
    contextual menu of  'Reference Location.1'.
    2. Activate the option of 'Pickable' in 'Graphic' tab
    of 'Properties' definition box.
    3. Click OK button.
    4. Sel the geometry of 'Reference Location.1' in
    graphics area.
    >> 'Reference Location.1' becomes pickble.
    .
    .
    

Local fix

Problem summary

  • Shape Design : the reference geometry becomes unpickable from g
    raphics area
    Summary of problem:
    'Reference Location.1' can be selected from
    specification tree, but is unpickable in graphical
    area. this is problem.
    .
    < Reproduction >
    1. Start CATIA V5
    2. Open the provided Part1.CATPart
    Workbench : 'GSD'.
    3. Sel 'Reference Location.1' in the unfold 'Mating
    Flange.1' in specification tree.
    >> confirm that 'Reference Location.1' is pickable.
    4. Click anywhere in graphics area.
    5. Sel the geometry of 'Reference Location.1' in
    graphics area.
    >> 'Reference Location.1' is unpickable in graphics
    area.
    >>> this is the problem.
    .
    < Desired Result >
    'Reference Location.1' is expected to be pickable in
    both specification tree and graphics area.
    .
    < Remarks >
    A by-pass is illustrated as follows:
    1. Choose the 'Properties' command from the
    contextual menu of  'Reference Location.1'.
    2. Activate the option of 'Pickable' in 'Graphic' tab
    of 'Properties' definition box.
    3. Click OK button.
    4. Sel the geometry of 'Reference Location.1' in
    graphics area.
    >> 'Reference Location.1' becomes pickble.
    .
    .
    

Problem conclusion

  • THIS PROBLEM WILL BE FIXED ON CATIA VERSION
    5 RELEASE 14 GA level.
    NOTE THAT THIS PROBLEM WILL ALSO BE FIXED
    ON V5R13SP02.
    .
    Incident Diagnosis
    Wrong properties management on reference
    location
    .
    Correction Explanation
    There has been a problem in the mating flange
    software.
    .
    Answer and By-Pass
    The problem is fixed now. OK from now for new
    created mating flange (the mating flange must be
    created again in order to take benefit of this
    correction). The Reference Location element is
    pickable now.
    By-pass : for the existing mating flange, pick
    attribut has to be manually changed.
    .
    .
    

Temporary fix

Comments

APAR Information

  • APAR number

    HD17363

  • Reported component name

    CATIA V5/NT/200

  • Reported component ID

    569151000

  • Reported release

    513

  • Status

    CLOSED PER

  • PE

    NoPE

  • HIPER

    NoHIPER

  • Special Attention

    NoSpecatt

  • Submitted date

    2004-02-05

  • Closed date

    2004-02-18

  • Last modified date

    2009-06-24

  • APAR is sysrouted FROM one or more of the following:

  • APAR is sysrouted TO one or more of the following:

Fix information

  • Fixed component name

    CATIA V5/NT/200

  • Fixed component ID

    569151000

Applicable component levels

  • R513 PSN SP51302

       UP04/03/22 N 1000