APAR status
Closed as documentation error.
Error description
ASSEMBLY DESIGN / MATERIAL : MATERIAL IS NOT VISIBLE WHEN SUBASSEMBLY IS OPENED IN NEW WINDOW. .
Local fix
Problem summary
ASSEMBLY DESIGN / MATERIAL : MATERIAL IS NOT VISIBLE WHEN SUBAS SEMBLY IS OPENED IN NEW WINDOW. ASSEMBLY DESIGN / MATERIAL : MATERIAL IS NOT VISIBLE WHEN SUBASSEMBLY IS OPENED IN NEW WINDOW. .
Problem conclusion
THIS MODIFICATION WILL BE INCLUDED IN CATIA DOCUMENTATION DELIVERED WITH CATIA VERSION 5 RELEASE 14. . INCIDENT DIAGNOSIS: ASSEMBLY DESIGN / MATERIAL : MATERIAL IS NOT VISIBLE WHEN SUBASSEMBLY IS OPENED IN NEW WINDOW. . DOCUMENTATION REFERNECE: Infrastructre / Real Time Rendering / Frequently Asked Questions / Where is stored a material applied onto a product . MODIFCATION: The last frequently asked question has been improved and now includes an example for greater clarity. . Two scenarios are found in this: Scenario 1: 1. File / open / Product2.CATProduct 2. Apply material to Product2.CATProduct. --> the material is applied on product2 node and stored in Product2.CATProduct (you agree) 3. View / render style / shading with material 4. Start / mechanical design / assembly design 5. Insert / existing component in Product.1 --> The material, applied on a sub-product node, is displayed in spec tree and in 3D window, due to step 3 6. Select product.2 open in new window --> The Product2 contains the material and it is displayed . Scenario 2 1. Start / mechanical design / assembly design 2. Insert / existing component in Product.1/ Product2 is inserted in Product1 3. Insert / new part / create new circular pad 4. Activate Product2 and apply material --> Material is applied on Product2, but stored in Product1.CATProduct. The Product2.CATProduct document is not modified, and "Save Management" command can show it to you. 5. View / render style / shading with material 6. Select product.2 open in new window --> The Product2 is displayed and do not contain any material. . Confusion here is that specification tree is exactly the same in step 5 of both scenaro, but the material has not been applied with same manner : in the first case, the material is stored in Product2, in the second case it is stored in Product1. . This is now documented properly. .
Temporary fix
Comments
APAR Information
APAR number
HD17349
Reported component name
CATIA V5/NT/200
Reported component ID
569151000
Reported release
512
Status
CLOSED DOC
PE
NoPE
HIPER
NoHIPER
Special Attention
NoSpecatt
Submitted date
2004-02-05
Closed date
2004-03-04
Last modified date
2004-03-04
APAR is sysrouted FROM one or more of the following:
APAR is sysrouted TO one or more of the following:
Fix information
Applicable component levels
[{"Business Unit":{"code":"BU053","label":"Cloud & Data Platform"},"Product":{"code":"SSVJ2K","label":"CATIA V5"},"Component":"","ARM Category":[],"Platform":[{"code":"PF025","label":"Platform Independent"}],"Version":"512","Edition":"","Line of Business":{"code":"LOB10","label":"Data and AI"}}]
Document Information
Modified date: