APAR status
Closed as program error.
Error description
Impossible to create a connect curve . Scenario : . 1. Open the provided CATPart file. >> Workbench is "Generative Shape Design". 2. Click the "Connect Curve" icon. >> The "Connect Curve Definition" window is displayed. 3. Edit it. Connect type : "Base Curve" Base Curve : "Join.18" First Curve : Point : "Point.42" Curve : "Default (None)" Second Curve : Point : "Point.43" Curve : "Default (None)" Click "OK". >> The "Update Error" appears. It is written as "Connect2: Use of curve: The input curve length is smaller than the geometry factory resolution. - Choose a curve with length greater than the geometry factory resolution." The "Update Error" should not appear. . There are edges that is smaller than 0.1mm. This problem is not reproduced if all edges are longer than 0.1mm. Is it spec? Impossible to find about "the geometry factory resolution" in the DOC. There is a porblem with the "geometry factory resolution". . .
Local fix
Problem summary
Cannot create connect curve Impossible to create a connect curve . Scenario : . 1. Open the provided CATPart file. >> Workbench is "Generative Shape Design". 2. Click the "Connect Curve" icon. >> The "Connect Curve Definition" window is displayed. 3. Edit it. Connect type : "Base Curve" Base Curve : "Join.18" First Curve : Point : "Point.42" Curve : "Default (None)" Second Curve : Point : "Point.43" Curve : "Default (None)" Click "OK". >> The "Update Error" appears. It is written as "Connect2: Use of curve: The input curve length is smaller than the geometry factory resolution. - Choose a curve with length greater than the geometry factory resolution." The "Update Error" should not appear. . There are edges that is smaller than 0.1mm. This problem is not reproduced if all edges are longer than 0.1mm. Is it spec? Impossible to find about "the geometry factory resolution" in the DOC. There is a porblem with the "geometry factory resolution". . .
Problem conclusion
THIS PROBLEM WILL BE FIXED ON CATIA VERSION 5 RELEASE 14 GA level. NOTE THAT THIS PROBLEM WILL ALSO BE FIXED ON V5R13SP02. . Incident Diagnosis connect curve (with base curve) has not been realizable because the selected curve was too small (l 10e-2 > catia.resolution = 10e-3) . Correction Explanation The base curve is not a nurbs, it must be converted. So, the conversion has been used with a tolerance for the specific cuvre size (10e-1). . Answer and By-Pass The problem is fixed now. . .
Temporary fix
Comments
APAR Information
APAR number
HD16446
Reported component name
CATIA V5/NT/200
Reported component ID
569151000
Reported release
512
Status
CLOSED PER
PE
NoPE
HIPER
NoHIPER
Special Attention
NoSpecatt
Submitted date
2004-01-19
Closed date
2004-02-09
Last modified date
2009-06-24
APAR is sysrouted FROM one or more of the following:
APAR is sysrouted TO one or more of the following:
Fix information
Fixed component name
CATIA V5/NT/200
Fixed component ID
569151000
Applicable component levels
R513 PSN SP51302
UP04/03/22 N 1000
[{"Business Unit":{"code":"BU053","label":"Cloud & Data Platform"},"Product":{"code":"SSVJ2K","label":"CATIA V5"},"Component":"","ARM Category":[],"Platform":[{"code":"PF025","label":"Platform Independent"}],"Version":"512","Edition":"","Line of Business":{"code":"LOB10","label":"Data and AI"}}]
Document Information
Modified date:
24 June 2009