Closed as Permanent restriction.
Error description
SKETCHER / EMPTY SKETCH CAN REMAIN IN TREE AFTER PERFORMING UNDO AND UPDATING PART . Scenario : ----------- 1) Open the sent CATPart 2) Click 'Sketch with Absolute Axis definition' icon : 3) Sel Line.1 and Line.2 as Reference in the tree. 4) Click 'OK'. 5) Click 'Circle' icon and create some circle 6) Click 'Undo' icon twice. ( Click until a workbench changes from 'Sketcher' to 'Part Design'. ) 7) update part if necessary === In spite of having returned before creating the sketch, the sketch remains in the tree. This is problem. It should disappear. . Remark : 8) double-click 'Sketch.1' in the tree. 9) Click 'Exit workbench'. == sketch has disappeared. .
Local fix
Problem summary
SKETCHER / EMPTY SKETCH CAN REMAIN IN TREE AFTER PERFORMING UNDO AND UPDATING PART SKETCHER / EMPTY SKETCH CAN REMAIN IN TREE AFTER PERFORMING UNDO AND UPDATING PART . Scenario : ----------- 1) Open the sent CATPart 2) Click 'Sketch with Absolute Axis definition' icon : 3) Sel Line.1 and Line.2 as Reference in the tree. 4) Click 'OK'. 5) Click 'Circle' icon and create some circle 6) Click 'Undo' icon twice. ( Click until a workbench changes from 'Sketcher' to 'Part Design'. ) 7) update part if necessary === In spite of having returned before creating the sketch, the sketch remains in the tree. This is problem. It should disappear. . Remark : 8) double-click 'Sketch.1' in the tree. 9) Click 'Exit workbench'. == sketch has disappeared. .
Problem conclusion
THIS PROBLEM IS PERMANENT RESTRICTION IN CATIA . Restriction Explanation During a sketch creation operation, there are actually 2 commands : - 1 - launch sketcher creation command (we create the sketch by clicking on Sketcher icon or on Sketch with absolute axis definition icon) . - 2 - launch sketcher edition command (this operation launch the sketcher workbench by selecting plane support or when defining the references of sketch). . But the Undo code handles commands independently : in case operations of one user are stored as 2 commands, 2 undo are necessary. There exist no relation between one command and another. This is a basis specification of the undo function and whole undo code cannot be changed for one and only specific case, the sketch creation. Thus it is a permanent restriction. . We understand that it is unusual for user, to obtain an empty sketch in tree by using undo command, although today it is not possible in a direct scenario to create a sketch in tree with no geometry in it. But no solution exist to solve this problem. . Remarks : - an empty sketch should not be a problem for user who can click a second time on undo or enter and exit sketch to make it disappear. - moreover to create empty sketch is being discussed at sketcher development team ; it could be implemented in a future release. In this case, to have empty sketch by performing undo would no longer be a problem. .
Temporary fix
Comments
APAR Information
APAR number
HD16167
Reported component name
CATIA V5/NT/200
Reported component ID
569151000
Reported release
511
Status
CLOSED PRS
PE
NoPE
HIPER
NoHIPER
Special Attention
NoSpecatt
Submitted date
2004-01-13
Closed date
2004-02-16
Last modified date
2004-02-16
APAR is sysrouted FROM one or more of the following:
APAR is sysrouted TO one or more of the following:
Fix information
Applicable component levels
[{"Business Unit":{"code":"BU053","label":"Cloud & Data Platform"},"Product":{"code":"SSVJ2K","label":"CATIA V5"},"Component":"","ARM Category":[],"Platform":[{"code":"PF025","label":"Platform Independent"}],"Version":"511","Edition":"","Line of Business":{"code":"LOB10","label":"Data and AI"}}]
Document Information
Modified date: