IBM Support

HD12120: WHEN "FORMULA" GO INTO "MULTIOUTPUT",CATIA IS ABEND

Subscribe

You can track all active APARs for this component.

 

APAR status

  • Closed as program error.

Error description

  • POINT OF THIS PROBLEM
    
    "Formula" should be able to be in line
    with "MultiOutput". But in this case,CATIA is ABEND
    when "Formula" is defined.
    
    PROCESS FOR REPRODUCTION.
    
    2. Open the CATPart file.
    
    3. Click "Translate" icon.
    >>"Translate Definition" window appears.
    
     4. Define in thewindow.
      a) Select "Line.2" and "Line.3" as "Element".
      b) Select "Line.1"as "Direction".
      c) Define "Formula" as "Distance"
      (1) Select "Edit formula" by MB3 on area
    of "Distance".
    >>"Relation location" window appears. The
    message is as follows.
    ---------------------------------------------
    
        Would you like the relation to be
        appened into the selected shape
        body?
    ---------------------------------------------
    
      (2) Click "(Y)" in the window.
    >>"Formula Editor" window appears.
      (3) Set as follows in the window.
    "Translate\Length"=length('Shape
    Body.1\Line.1')
      (4) Click OK in the window.
    >>"A check on data will be launched on active
    document" window appears.
    
    Message is "Command interrupted".
      >>This means "CATIA is ABEND".
      >>>This is problem.
    .
    
    EXPECTED RESULT
     "CATIA isn't ABEND" and "Formula" should be
    created before Multi Output.1(Translate).
    
    
    
             .
    

Local fix

Problem summary

  • GSD : When "Formula" go into "MultiOutput",CATIA is ABEND
    
    POINT OF THIS PROBLEM
    
    "Formula" should be able to be in line
    with "MultiOutput". But in this case,CATIA is ABEND
    when "Formula" is defined.
    
    PROCESS FOR REPRODUCTION.
    
    1. Start CATIA
    
    2. Open the CATPart file.
    
    3. Click "Translate" icon.
    >>"Translate Definition" window appears.
    
     4. Define in thewindow.
      a) Select "Line.2" and "Line.3" as "Element".
      b) Select "Line.1"as "Direction".
      c) Define "Formula" as "Distance"
      (1) Select "Edit formula" by MB3 on area
    of "Distance".
    >>"Relation location" window appears. The
    message is as follows.
    ---------------------------------------------
    
        Would you like the relation to be
        appened into the selected shape
        body?
    ---------------------------------------------
    
      (2) Click "(Y)" in the window.
    >>"Formula Editor" window appears.
      (3) Set as follows in the window.
    "Translate\Length"=length('Shape
    Body.1\Line.1')
      (4) Click OK in the window.
    >>"A check on data will be launched on active
    document" window appears.
    
    Message is "Command interrupted".
      >>This means "CATIA is ABEND".
      >>>This is problem.
    .
    
    EXPECTED RESULT
     "CATIA isn't ABEND" and "Formula" should be
    created before Multi Output.1(Translate).
    
    
    
    
    
    
    
    .
    

Problem conclusion

  • THIS PROBLEM WILL BE FIXED ON CATIA VERSION 5 RELEASE 13 GA lev
    el.
    NOTE THAT THIS PROBLEM WILL ALSO BE FIXED ON V5R12SP03.
    .
    Incident Diagnosis
    When Formula go into MultiOutput ,CATIA is ABEND.
    .
    Correction Explanation
    Formula is agregated under the multioutput and so
    the list of children is increased which leads to a
    crash...
    .
    Answer and By-Pass
    None.
    .
    Best Regards.
    
    .
    

Temporary fix

Comments

APAR Information

  • APAR number

    HD12120

  • Reported component name

    CATIA V5/NT/200

  • Reported component ID

    569151000

  • Reported release

    512

  • Status

    CLOSED PER

  • PE

    NoPE

  • HIPER

    NoHIPER

  • Special Attention

    NoSpecatt

  • Submitted date

    2003-10-01

  • Closed date

    2003-10-27

  • Last modified date

    2003-11-18

  • APAR is sysrouted FROM one or more of the following:

  • APAR is sysrouted TO one or more of the following:

Fix information

  • Fixed component name

    CATIA V5/NT/200

  • Fixed component ID

    569151000

Applicable component levels

  • R512 PSN SP51203

       UP03/11/18 I 1000

[{"Business Unit":{"code":"BU053","label":"Cloud & Data Platform"},"Product":{"code":"SSVJ2K","label":"CATIA V5"},"Component":"","ARM Category":[],"Platform":[{"code":"PF025","label":"Platform Independent"}],"Version":"512","Edition":"","Line of Business":{"code":"LOB10","label":"Data and AI"}}]

Document Information

Modified date:
18 November 2003