HD11291: PARTDESIGN / INSTANTIATION FAILURE OF POWERCOPY WITH CHAMFER OR EDGE FILLET :" DESTINATION IS NOT VALID " ERROR

Subscribe

You can track all active APARs for this component.

 

APAR status

  • Closed as program error.

Error description

  • A power copy from a chamber or from an edge
    fillet cannot be instantiated.
    .
    Scenario from scratch :
    --------------------------
    1. create arbitrary pad
    2. Create chamfer on one edge
    3. Insert-> Advanced Replication Tools-> Power
    Copy
    4.Select the Chamfer.1 in tree
    5. Instantiate the created powercopy by selecting
    another edge
    == "Instantiation cannot be performed. The
    destination is not valid" error occurs.
    .
    Remarks :
    - On step.4, on previous CATIA levels, this
    powercopy could not even be created : this error
    message occured at creation :
    "Error in definition :
    -Some element could not be replaced during
    instantiation. Include them in the powercopy to
    avoid this problem.
    CstEdgeRibbon.1 (ObjectList) does not implement
    replace for Pad.1\Edge.1"
    .
    - Same problem happens with Edge fillet, but in
    the documentation no restriction about the creation
    of power copy with chamfers and fillets has been
    found.
    
    .
    

Local fix

Problem summary

  • PARTDESIGN / INSTANTIATION FAILURE OF POWERCOPY WITH CHAMFER OR
     EDGE FILLET :" DESTINATION IS NOT VALID " ERROR
    A power copy from a chamber or from an edge
    fillet cannot be instantiated.
    .
    Scenario from scratch :
    --------------------------
    1. create arbitrary pad
    2. Create chamfer on one edge
    3. Insert-> Advanced Replication Tools-> Power
    Copy
    4.Select the Chamfer.1 in tree
    5. Instantiate the created powercopy by selecting
    another edge
    == "Instantiation cannot be performed. The
    destination is not valid" error occurs.
    .
    Remarks :
    - On step.4, on previous CATIA levels, this
    powercopy could not even be created : this error
    message occured at creation :
    "Error in definition :
    -Some element could not be replaced during
    instantiation. Include them in the powercopy to
    avoid this problem.
    CstEdgeRibbon.1 (ObjectList) does not implement
    replace for Pad.1\Edge.1"
    .
    - Same problem happens with Edge fillet, but in
    the documentation no restriction about the creation
    of power copy with chamfers and fillets has been
    found.
    
    .
    

Problem conclusion

  • THIS PROBLEM WILL BE FIXED ON CATIA
    VERSION 5 RELEASE 13 GA level.
    NOTE THAT THIS PROBLEM WILL ALSO BE FIXED
     ON V5R12SP03 .
    .
    Problem has been fixed for chamfer and edge fillet :
    Powercopy composed of a chamfer or of an edge fillet
    can now correctly be instantiated..
    
    .
    

Temporary fix

Comments

APAR Information

  • APAR number

    HD11291

  • Reported component name

    CATIA V5/NT/200

  • Reported component ID

    569151000

  • Reported release

    511

  • Status

    CLOSED PER

  • PE

    NoPE

  • HIPER

    NoHIPER

  • Special Attention

    NoSpecatt

  • Submitted date

    2003-09-16

  • Closed date

    2003-10-28

  • Last modified date

    2003-11-18

  • APAR is sysrouted FROM one or more of the following:

  • APAR is sysrouted TO one or more of the following:

Fix information

  • Fixed component name

    CATIA V5/NT/200

  • Fixed component ID

    569151000

Applicable component levels

  • R512 PSN SP51203

       UP03/11/18 I 1000

[{"Business Unit":{"code":"BU053","label":"Cloud & Data Platform"},"Product":{"code":"SSVJ2K","label":"CATIA V5"},"Component":"","ARM Category":[],"Platform":[{"code":"PF025","label":"Platform Independent"}],"Version":"511","Edition":"","Line of Business":{"code":"LOB10","label":"Data and AI"}}]

Document Information

Modified date:
18 November 2003